F-J-C
Minimum response time
Setting of this parameter avoids interference of communication at the RS-485 interface. For this pur-
pose the response to a command is delayed by the selected time. Additionally, the response is kept
compact.
Unit
ms
Milliseconds
Value range
0…2ˈ000
10 (default)
F-J-D
Transmitter warm-up time
The transmitter warm-up time defines the time before data is sent.
Unit
ms
Milliseconds
Value range
0…2ˈ000
10 (default)
F-J-E
Flow control
The XOFF-XON flow control can be activated with this setting.
Option
Description
Off (default)
no flow control
XOFF-XON blocking
XOFF-XON flow control, especially adapted for half-duplex systems
F-J-F
Sending window
If XON-XOFF flow control is activated data are transmitted in blocks with the defined length.
Unit
ms
Milliseconds
Value range
200…5ˈ000
300 (default)