Copyright © 2010 Somfy SAS. All rights reserved.
Sunea screen io
8
EN
Advanced functions
7.4.
Please contact the manufacturer of the awning before using these functions, to confirm the
compatibility of your installation.
or
or
0.5 s
5 s
1
2
3
4
1
2
To activate this function:
1) Put the awning in the upper end limit position.
2) Press the «my» and Down buttons simultaneously until the awning moves.
If the «Back release» function was inactive, it is activated.
-
If the «Back release» function was active, it is deactivated.
-
«Closing force» function for vertical awnings with upper stop only
7.4.2.
This function can be used to increase or decrease the load bar’s force under the head
rail, with 3 thresholds (high-medium-low).
The motor’s default factory setting is low level.
For safety reasons, this function can only be accessed via the Somfy io control point in 3 scenarios:
After the 2-second settings validation stop and
•
before programming the first Somfy io control
point.
After programming the first Somfy io control point
•
and for the next 4 cycles.
After a single power cut, and for the next 4
•
cycles.
To activate this function:
1) Put the awning in the middle position.
2)
Briefly press the «my» and Up buttons
simultaneously, then immediately afterwards press
and hold the «my» and Up buttons until the awning
moves.
The motor is in programming mode for just 10 s.
For safety reasons, this function can only be activated or
deactivated via the io control point in 3 scenarios:
After the 2-second settings validation stop and before
•
programming the first Somfy io control point.
After programming the first Somfy io control point and
•
for the next 4 cycles.
After a single power cut, and for the next 4 cycles.
•
«Back release» function, for vertical awnings with upper stop only
7.4.1.
This function releases the fabric tension after closing an awning with upper stop (load bar
stopped under the head rail).
The procedure to follow to activate or deactivate «Back release» is identical.
3) Adjust the closing force using the Up or Down buttons.
- To increase the closing force, press the Up button until the awning moves slowly: the cassette
awning closing force is increased to the upper threshold.
- To decrease the closing force, press the Down button until the awning moves slowly: the cassette
awning closing force is decreased to the lower threshold.
4) Press the «my» button until the awning moves: the new closing force has been programmed.
Summary of Contents for Sunea io