18
Copyright © 2013 Somfy SAS. All rights reserved.
Commissioning
7
Switching the installation on
The indicator light flashes (twice).
The motor is switched on and awaiting auto-programming.
If the indicator light does not come on or the number of flashes is not as expected: see diagnostic page 29.
Auto-programming the gate leaves' travel
m ADJUSTING THE OPENING STOP
Opening end stop
The opening stops are
integrated into the cylinder
. They
delimit the travel of the gate leaf when opening
.
Reminder: Your installation must be equipped with closing stops secured to the ground to mark out the travel of the gate when closing.
Press button 1 on the remote control.
After a few seconds, the first gate leaf opens, slowly.
If the gate leaf does not open, check that the motors are wired as
shown on page 16.
1
Press button 1 on the remote control again to stop the gate leaf in
the desired opening position.
During this phase, pressing button 1 on the programmed remote control button 1 only causes the gate to open and stop (1st press = open, 2nd press
= stop, 3rd press = open, 4th press = stop, etc.), you can therefore set the desired opening position in several increments. it will be possible to close
the gate once the opening stops are installed.
STOP
Button 1
The remote controls supplied with the kit are already memorised and
programmed so that button 1 on the remote controls activates full opening of
the gate.
Position the opening stops in contact with the cylinder knob, then
tighten the stops with a 3 mm Allen key (2 screws per stop).
3
Turn the Allen key
twice after contact.
2