background image

• Align the chain head (A) with the frame

fitting (B).

•   Close the window by exerting a certain 

amount of pressure and insert the safety 
split pin (E).

•   Connect the actuator to the mains supply as

shown in the enclosed wiring diagrams and in
compliance with safety standards.

•   Run the actuator to the end of stroke to open 

the window and close it again. This operation 
tests that the actuator is working correctly and 
that the window is closing properly.

Danger!

Danger of hands being crushed.
When the window is moving do not
insert your hand between the fixed
frame and the moving parts.

Checking the operating efficiency of the limit
switches of the Linkeo 2 actuator.

• The Linkeo 2 actuator is fitted with two limit

switches that stop opening and closing at the
beginning and the end of the stroke. It is
therefore necessary to ensure that the internal
microswitches disconnect the power supply to
the motor when the fully opened and fully 
closed positions are reached.
The internal microswitches disconnect the  
power supply to the motor when the fully 
opened and fully closed positions are 
reached. When the fully opened or fully closed 
positions are reached, you will feel the motor 
making the outer structure vibrate if you lay 
your hand on it.

•   If the motor does not cut out when the end of

stroke is reached, proceed as follows:
1) Disconnect the actuator from the power
supply.
2) Immediately contact SOMFY Technical-
Sales Department.

•   If the window does not close correctly,

proceed as follows:
1) Remove safety split pin (E).
2) Use the control push-button to make the

actuator open and close completely.

3) Close the window by exerting a certain

amount of pressure.

4) Insert the safety split pin (E)

Warning!

The actuator is not a structural member
of the window. Mount the safety armsin
bottom-hung applications.

B

FITTING TO A HOPPER-FRAME
WINDOW

INSTRUCTIONS ON FITTING, USING AND
MAINTAINING THE ACTUATOR

Linkeo 2

A08

A09

4

Warning!

The plugs underneath must be left in
their housing to prevent the covers from
being moved.

• If the material of the sill enables it, fix the 

actuator to the sill by inserting the screws (30) 
(not supplied) and tightening them. The screws  
will perforate the plastic plugs that have been 
left in their  housing. Otherwise, drill using the 
four holes on the actuator as a drilling template, 
insert the screws (30) (not supplied) and tighten.

•   Close the screw holes by inserting the plugs

(D) on the side where the screws are inserted.

A06

A07

•  Insert a screwdriver into the slits on the cover 

and remove the plastic protective plugs (D).    
Take care to remove only the protective plugs 
on the side where the screws are inserted, 
opposite to the actuator support surface.

A05

•   Find and trace the centre line of the window 

and the fixed frame.

•   Drill holes in the places indicated on the 

drawing using drill bits of the required 
diameter, as per the following scheme:

B01

B02

Summary of Contents for Linkeo 2

Page 1: ...States SOMFY SYSTEMS Inc www somfysystems com Canada SOMFY ULC www somfy com India SOMFY INDIA PVT Ltd www somfy com Russia cf Germany SOMFY GmbH www somfy de Cyprus SOMFY MIDDLE EAST www somfy com It...

Page 2: ...ONS POUR L AUTOMATION DES MENUISERIES L SUNGEN F R DIE AUTOMATION FENSTERN OPLOSSINGEN VOOR AUTOMATISCH SLUITEN EN OPENEN SOLUCIONES PARA LAAUTOMACI N DE LOS CERRAMIENTOS USE AND INSTALLATION MANUAL G...

Page 3: ...A04 A05 A06 A01 A02 A03 A A00 B A C E 1 2 3 1 2 3 AF 4 8 x 13 AF 3 5 x 16 M5 x 10...

Page 4: ...A07 A08 A09...

Page 5: ...B04 B05 B06 B01 B02 B03 B B00 2 3 4 AF 3 5 x 16 M5 x 10 AF 4 8 x 22 G A 4 F C 2 3...

Page 6: ...B07 B08 C01 C02 C03 c C00 1 3 AF 4 8 x 13 M5 x 10 E A B C 4 3 H 5 1 4 5 TCCE M4 x 6 AF 4 2 x 9 5...

Page 7: ...C04 C05 C06 C07 C08 C09...

Page 8: ...ENGLISH FRAN AIS DEUTSCH DUTCH ESPA OL 1 2 12 22 32 42...

Page 9: ...m hung applications The position of the threeway switch buttons must be outside the field of action of the moving part of the window Do not let children play with fixed controls wall controls and keep...

Page 10: ...and injury to the operator In case of installation of the actuator on a window wich is installed at less then 2 5 meters from ground level or other level access the actuator must be controlled esclusi...

Page 11: ...nect the actuator from the power supply 2 Immediately contact SOMFY Technical Sales Department If the window does not close correctly proceed as follows 1 Remove safety split pin E 2 Use the control p...

Page 12: ...h two limit switches that stop opening and closing at the beginning and the end of the stroke It is therefore necessary to ensure that the internal microswitches disconnect the power supply to the mot...

Page 13: ...acket C onto the spacer using the screws 4 supplied Fix the actuator in this position by using an Allen wrench not supplied to tighten the hexagonal head dowels 3 on the back of the bracket Align chai...

Page 14: ...r the installation of changeover switches with mid OFF position with man present control or equivalent The position of the three way switch buttons must be outside the field of action of the moving pa...

Page 15: ...mid OFF position a opens b closes C Bipolar main power supply switch with minimum contact opening of 3 mm Linkeo 2 D01 D02 8 WIRING DIAGRAMS LINEKO 2 230V AC Power supply voltage shown on the rating...

Page 16: ...the electric load and length of the line B Bipolar switch with mid OFF position a opens b closes D03 D04 WIRING DIAGRAMS LINKEO 2 24V DC CONDUCTORS COMPARATIVE TABLE LINKEO 2 24V DC COLOUR NUMBER SIGN...

Page 17: ...the end position is reached open closed open completely extended chain closed completely retracted chain Available opening strokes between 200 and 250 mm Actuator ratings plate SPECIFICATIONS Linkeo 2...

Page 18: ...ERRORS TO BE AVOIDED Assembly not aligned with actuator Double control switch is not interlocked SPECIFICATIONS Linkeo 2 11...

Reviews: