•   Screw the bracket (F) to the window using the

screws (4) supplied (only for aluminium
windows). Use screws of a suitable type and
length for windows made of a different 
material.

•   Screw the bracket (C) to the fixed frame using 

the screws (2) supplied (only for aluminium
windows). Use screws of a suitable type and
length for windows made of a different 
material.

•   Slide the actuator in the guide provided to  

insert it into the bracket (C) until chain (A)   
head is centred to the opening for the 
window (F) attachment.

•   Fix the actuator in this position by using the   

Allen wrench (not supplied) to tighten the 

hexagonal-head dowels (3) in the threads 
provided on the back of the bracket.

Danger!

Danger of hands being crushed.
When the ledge is moving, never put
your hands between the fixed frame
and the moving parts.
•   If the window does not close 

correctly, proceed as follows: 
1) Remove safety split pin (G).
2) Use the control push-button to 
open and close the actuator
completely
3) Close the window by exerting a 
certain pressure manually
4) Insert safety split pin (G).

Check that the operating efficiency of the
Linkeo 2 actuator.

• The Linkeo 2 actuator is fitted with two limit

switches that stop opening and closing at the
beginning and the end of the stroke. It is
therefore necessary to ensure that the internal
microswitches disconnect the power supply to
the motor when the fully opened and fully 
closed positions are reached.
When the fully opened or fully closed 
positions are reached, you will feel the motor 
making the outer structure vibrate if you lay 
your hand on it.
If the motor is still live when end of stroke is
reached, proceed as follows:
1) Disconnect the actuator.
2) Contact the SOMFY Technical-Sales
Department.

Window

Screws

Bits

(diameter mm)

- Moving part

AF 4.8 X 22

UNI 6954 

( 4 )

3 . 8

- Fixed part

AF 3.5 X 16

UNI 6954 

( 2 )

2 . 7

- Window centre line

INSTRUCTIONS ON FITTING, USING AND
MAINTAINING THE ACTUATOR

Linkeo 2

B03

B04

B05

B06

B07

B08

5

• Align chain head (A) to window attachment.
•   Close the window by exerting a certain 

amount of pressure, then insert split pin (G).

•   Connect the actuator to the mains supply as

shown in the enclosed wiring diagrams and in
compliance with safety standards.

•   Run the actuator until it is fully extended to 

open the window and close it again. This 
operation checks the correct working of the  
actuator, limit switches and that the window is 
closing properly.

Warning!

Window closing can be further adjusted
by lengthening or shortening the
telescopic bracket (F)

Summary of Contents for Linkeo 2

Page 1: ...States SOMFY SYSTEMS Inc www somfysystems com Canada SOMFY ULC www somfy com India SOMFY INDIA PVT Ltd www somfy com Russia cf Germany SOMFY GmbH www somfy de Cyprus SOMFY MIDDLE EAST www somfy com It...

Page 2: ...ONS POUR L AUTOMATION DES MENUISERIES L SUNGEN F R DIE AUTOMATION FENSTERN OPLOSSINGEN VOOR AUTOMATISCH SLUITEN EN OPENEN SOLUCIONES PARA LAAUTOMACI N DE LOS CERRAMIENTOS USE AND INSTALLATION MANUAL G...

Page 3: ...A04 A05 A06 A01 A02 A03 A A00 B A C E 1 2 3 1 2 3 AF 4 8 x 13 AF 3 5 x 16 M5 x 10...

Page 4: ...A07 A08 A09...

Page 5: ...B04 B05 B06 B01 B02 B03 B B00 2 3 4 AF 3 5 x 16 M5 x 10 AF 4 8 x 22 G A 4 F C 2 3...

Page 6: ...B07 B08 C01 C02 C03 c C00 1 3 AF 4 8 x 13 M5 x 10 E A B C 4 3 H 5 1 4 5 TCCE M4 x 6 AF 4 2 x 9 5...

Page 7: ...C04 C05 C06 C07 C08 C09...

Page 8: ...ENGLISH FRAN AIS DEUTSCH DUTCH ESPA OL 1 2 12 22 32 42...

Page 9: ...m hung applications The position of the threeway switch buttons must be outside the field of action of the moving part of the window Do not let children play with fixed controls wall controls and keep...

Page 10: ...and injury to the operator In case of installation of the actuator on a window wich is installed at less then 2 5 meters from ground level or other level access the actuator must be controlled esclusi...

Page 11: ...nect the actuator from the power supply 2 Immediately contact SOMFY Technical Sales Department If the window does not close correctly proceed as follows 1 Remove safety split pin E 2 Use the control p...

Page 12: ...h two limit switches that stop opening and closing at the beginning and the end of the stroke It is therefore necessary to ensure that the internal microswitches disconnect the power supply to the mot...

Page 13: ...acket C onto the spacer using the screws 4 supplied Fix the actuator in this position by using an Allen wrench not supplied to tighten the hexagonal head dowels 3 on the back of the bracket Align chai...

Page 14: ...r the installation of changeover switches with mid OFF position with man present control or equivalent The position of the three way switch buttons must be outside the field of action of the moving pa...

Page 15: ...mid OFF position a opens b closes C Bipolar main power supply switch with minimum contact opening of 3 mm Linkeo 2 D01 D02 8 WIRING DIAGRAMS LINEKO 2 230V AC Power supply voltage shown on the rating...

Page 16: ...the electric load and length of the line B Bipolar switch with mid OFF position a opens b closes D03 D04 WIRING DIAGRAMS LINKEO 2 24V DC CONDUCTORS COMPARATIVE TABLE LINKEO 2 24V DC COLOUR NUMBER SIGN...

Page 17: ...the end position is reached open closed open completely extended chain closed completely retracted chain Available opening strokes between 200 and 250 mm Actuator ratings plate SPECIFICATIONS Linkeo 2...

Page 18: ...ERRORS TO BE AVOIDED Assembly not aligned with actuator Double control switch is not interlocked SPECIFICATIONS Linkeo 2 11...