• Screw the bracket (F) to the window using the
screws (4) supplied (only for aluminium
windows). Use screws of a suitable type and
length for windows made of a different
material.
• Screw the bracket (C) to the fixed frame using
the screws (2) supplied (only for aluminium
windows). Use screws of a suitable type and
length for windows made of a different
material.
• Slide the actuator in the guide provided to
insert it into the bracket (C) until chain (A)
head is centred to the opening for the
window (F) attachment.
• Fix the actuator in this position by using the
Allen wrench (not supplied) to tighten the
hexagonal-head dowels (3) in the threads
provided on the back of the bracket.
Danger!
Danger of hands being crushed.
When the ledge is moving, never put
your hands between the fixed frame
and the moving parts.
• If the window does not close
correctly, proceed as follows:
1) Remove safety split pin (G).
2) Use the control push-button to
open and close the actuator
completely
3) Close the window by exerting a
certain pressure manually
4) Insert safety split pin (G).
Check that the operating efficiency of the
Linkeo 2 actuator.
• The Linkeo 2 actuator is fitted with two limit
switches that stop opening and closing at the
beginning and the end of the stroke. It is
therefore necessary to ensure that the internal
microswitches disconnect the power supply to
the motor when the fully opened and fully
closed positions are reached.
When the fully opened or fully closed
positions are reached, you will feel the motor
making the outer structure vibrate if you lay
your hand on it.
If the motor is still live when end of stroke is
reached, proceed as follows:
1) Disconnect the actuator.
2) Contact the SOMFY Technical-Sales
Department.
Window
Screws
Bits
(diameter mm)
X
- Moving part
AF 4.8 X 22
UNI 6954
( 4 )
3 . 8
Y
- Fixed part
AF 3.5 X 16
UNI 6954
( 2 )
2 . 7
Z
- Window centre line
INSTRUCTIONS ON FITTING, USING AND
MAINTAINING THE ACTUATOR
Linkeo 2
B03
B04
B05
B06
B07
B08
5
• Align chain head (A) to window attachment.
• Close the window by exerting a certain
amount of pressure, then insert split pin (G).
• Connect the actuator to the mains supply as
shown in the enclosed wiring diagrams and in
compliance with safety standards.
• Run the actuator until it is fully extended to
open the window and close it again. This
operation checks the correct working of the
actuator, limit switches and that the window is
closing properly.
Warning!
Window closing can be further adjusted
by lengthening or shortening the
telescopic bracket (F)
Summary of Contents for Linkeo 2
Page 3: ...A04 A05 A06 A01 A02 A03 A A00 B A C E 1 2 3 1 2 3 AF 4 8 x 13 AF 3 5 x 16 M5 x 10...
Page 4: ...A07 A08 A09...
Page 5: ...B04 B05 B06 B01 B02 B03 B B00 2 3 4 AF 3 5 x 16 M5 x 10 AF 4 8 x 22 G A 4 F C 2 3...
Page 7: ...C04 C05 C06 C07 C08 C09...
Page 8: ...ENGLISH FRAN AIS DEUTSCH DUTCH ESPA OL 1 2 12 22 32 42...