Dexxo Pro io
11
Copyright © 2015 Somfy SAS. All rights reserved
EN
> To determine the operating mode in which a button is
programmed
When the saved button and the “
STOP
´ EXWWRQ RQ WKH UHPRWH FRQWURO DUH
VLPXOWDQHRXVO\SUHVVHGLIWKHUHPRWHFRQWURO
- beeps twice, the button is programmed for partial opening,
- beeps 3 times, the button is programmed for full opening.
10 - SPECIAL OPERATION
If there is a power outage while the door is being opened, when the power is
restored the door should return to its opening stop; if the door does not reach
its opening stop, it cannot be closed.
)RURWKHUVSHFLÀFRSHUDWLRQVVHHWKHXVHUPDQXDO
11 - CLEARING REMOTE CONTROLS AND
ALL SETTINGS
11.1 Clearing remote controls - Fig. 48 to 50
> Clearing Keytis or Keygo remote controls
Individually clearing a remote control button
7KLVFDQEHGRQH
- by programming from the Dexxo Pro motor
(Fig. 20)
.
Programming a previously programmed button automatically clears any
previously stored programming settings.
- by directly clearing the remote control (only for Keytis remote controls)
(
Fig. 48)
.
Simultaneously press the “
PROG
´EXWWRQDQGWKH
BUTTON
to be cleared on
the remote control.
> Clearing all remote controls (Fig. 49)
[1].
Press the “
PROG
´ EXWWRQ RQ 'H[[R 3UR XQWLO WKH OLJKW EOLQNV VHYHQ
VHFRQGV7KLVZLOO
- Clear the system key memorised by Dexxo Pro,
- Clear the programming for all memorised remote controls.
[2].
For Keytis remote controls, repeat the direct clearing procedure for all of
WKH.H\WLVUHPRWHFRQWUROEXWWRQVSURJUDPPHGRQWKH'H[[R3URV\VWHP
Fig. 48
.
> Keytis remote control general reset (Fig. 50)
Simultaneously press the “
PROG
´DQG³
KEY
´EXWWRQV7KLVZLOO
- perform a program general clear action (all buttons),
- clear all settings from the remote control (refer to Keytis io remote control
documentation),
- change the system key memorised by the remote control.
11.2 Resetting all settings - Fig. 51
Press the “
SET
´EXWWRQXQWLOWKHOLJKWJRHVRXWV
This clears all previously stored settings and returns them to their default
values.
12 - LOCKING PROGRAMMING - FIG. 52
WARNING
The keypad must be locked to ensure the safety of the end-users.
Non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
Pressing the “
SET
´³´
“-”
buttons
- start by pressing “
SET
´
- the
“+”
and
“-”
buttons must be pressed simultaneously within 2 seconds.
To access programming mode once again, repeat the same procedure.
13 - REFITTING COVERS
5H¿WWKHPRWRUKHDGDQGEXLOWLQOLJKWFRYHUV
(Fig. 53).
14 - TROUBLESHOOTING
14.1 Operating codes displayed
Code
Description
Comments
Waiting for a command
Door opening
Waiting for the door to close
Door closing
Obstacle detection
Displayed during obstacle
detection then for 30 s.
Safety input active
Displayed after a movement
request or during movement, when
the safety input is active.
This display is maintained as long
as the safety input is active.
Pedestrian door safety
contact active
Displayed after a movement
request or during movement, when
the pedestrian door contact is
open.
The display is maintained as long
as the pedestrian door contact
remains open.
Safety mechanism self test
Displayed during safety
mechanism self tests.
Working from back-up battery
Waiting for a command
14.2 Programming codes displayed
Code
Description
Comments
Awaiting setting
Pressing the “
SET
´EXWWRQIRUVVWDUWVWKH
learning mode.
Learning mode
Pressing the “
OK
´EXWWRQVWDUWVWKHOHDUQLQJ
F\FOHWKH6GLVSOD\EOLQNVGXULQJWKHHQWLUH
cycle.
Pressing the “
+
´RU
“-”
buttons will control the
motor in forced mode.
Awaiting motor
control memorisation
Pressing a remote control button will assign
this button to motor control.
Add a remote
control
Displayed during remote control
programming. (One-way controls).
Delete a remote
control
Displayed during remote control deletion.
(One-way controls)
One-way control
memory full
Displayed on reaching the maximum number
of channels that can be saved.
One-way control
memory empty
Displayed when all the one-way remote
controls have been deleted.
14.3 Error and failure codes displayed
Code
Description
Comments
Action required?
Maximum
force reached
During learning,
the door requires
too much force for
the motor.
Check door balance and
correct operation by manual
operation.
Safety
mechanism
self test fault
The safety device
self test failed
Check that “
P2
´LVVHWXS
correctly depending on the
devices connected to the safety
input.
Check safety device wiring.
When photoelectric cells
are used, check their proper
alignment.
Other faults
and failure
conditions
These codes
correspond to
various electronic
circuit board
failures.
Cut the power supply (mains &
battery back-up), wait for a few
minutes then re-connect the
power supply.
If the fault persists, contact
Somfy Technical Support.
For any other error or failure code, please contact Somfy