EN
11
Copyright © 2008 Somfy SAS. All rights reserved.
LOGIC MENU (LoGIc)
Press
"OK"
to display one of the following submenus:
Display
By default
Description
Automatic closure
(tcA)
OFF
Automatic closure mode operation.
The gate will close automatically once the programmed time delay (tcA) times out.
ON
: after a time delay, triggers automatic closure
OFF
: switches off automatic closure
3 steps
(3 StEP)
OFF
“3 step”: semi-automatic mode operation (refer to the User's Manual).
“4 step”: sequential mode operation (refer to the User's Manual).
ON
: Switches on 3 step logic. Pressing START once has the following effect:
gate closed: the gate opens
•
gate moving (opening): the gate stops and the automatic closure time is switched on (only if
•
the latter function is set to ON)
gate open: the gate closes
•
gate moving (closing): the gate stops and opens again
•
OFF
: Switches on 4 step logic. Pressing START once has the following effect:
gate closed: the gate opens
•
gate moving (opening): the gate stops and the automatic closure time is switched on
•
(only if the latter function is set to ON)
gate open: the gate closes
•
gate moving (closing): the gate stops and the automatic closure time is not switched on
•
once the gate stops moving: the gate opens
•
Pushbutton inhibit
(IbL oPEn)
OFF
Blocks out pushbutton functions while the gate is opening.
ON
: while opening only
OFF
: no inhibit function
Fast closure
(FASt cLS)
OFF
The gate closes three seconds after clearing the photoelectric cells and before reaching the
end of the con
fi
gured automatic closure time.
ON
: command enabled
OFF
: command disabled
Photoelectric cells
during opening
(Photoc. oPEn)
OFF
ON
:
in closing mode, the gate stops then reverses its movement.
•
in opening mode, cells are inactive.
•
OFF
:
•
in closing mode, the gate stops and reverses its movement once the cells are no longer
obstructed.
in opening mode, the gate stops then continues its movement once the cells are no longer
•
obstructed.
Photoelectric cell tests
(tESt Phot)
OFF
Activates the photoelectric cell test.
ON
: command enabled
OFF
: command disabled