E
n
g
li
s
h
5
Copyright © 2013 Somfy SAS. All rights reserved.
10 cm mini
Entaille
du pilier
STOP
Cellules photoélectriques
ZONE 1
Risks of impact and crushing
ZONE 2
Risks of crushing and cutting
of hands
ZONE 3
Risk of impact
Solution:
If there a cutting risk zone on the
installation:
- leave a distance of at least 10 cm
between the leaf and the pillar/
wall
- cut off the corner of the pillar
without weakening it.
Solution:
Obstacle detection built
into the motor
Solution:
Obstacle detection built into the
motor
Photoelectric cells
STOP
Measures to be taken to counter risks
50 cm
mini
ZONE 4
Risk of trapping and crushing
ZONE 5
Risk of feet being
trapped
Solution:
Obstacle detection built into the motor
If there is a area between the gate leaves
and the surrounding fixed elements
where someone could get trapped, you
must leave a minimum distance of 50
cm between the gate leaves and the fixed
sections.
Solution:
If there is an area where feet could be
trapped between the bottom of the gate
leaves and the ground, you must leave a
distance between the bottom of the gate
leaves and the ground of a minimum of
12 cm or a maximum of 5 mm.
12 cm
min.
12 cm
min.
5 mm
max.
Photoelectric cells
Removed
edge of the
pillar