24
Copyright © 2013 Somfy SAS. All rights reserved.
Offset aerial
Solar power
The aerial wire can be replaced with an offset aerial with a greater range.
This is placed on top of the pillar and must be clearly accessible.
It is connected to terminals 1 and 2 (blue "ANT" label) on the control unit:
- the wire core on terminal 1,
- the ground strap on terminal 2.
When the motor is running on the solar feed:
• only the remote controls and radio control points can be used to control the
gate (wired controls are deactivated),
• the wired safety accessories (photoelectric cells, orange light) remain active.
Video entry phone
This accessory is not compatible with solar power.
Only connect one non-powered dry contact.
Never connect your motor to a 230 V power supply when it is connected to a solar power supply, as this may damage the
motor's electronics unit.
NC COM NO