![SOMFY Axroll Manual Download Page 4](http://html1.mh-extra.com/html/somfy/axroll/axroll_manual_1317546004.webp)
4
■
Programming
Parameter
scroll buttons
Value scroll buttons
The Axroll is factory configured with default settings corresponding to the
requirements of the installation.
The remote controls require programming.
The Axroll operational parameters can be adjusted to create a
personalised control scenario corresponding to the accessories which
have been connected (see complementary parameters p. 8).
The Axroll parameters can be defined during the
installation process in any order of preference.
Use the
or
buttons to browse the menu and
display the parameter required.
Use the
or
buttons to change the value of the
parameter.
The last value is recorded automatically (the display is
fixed when pressing the buttons).
Ensure that the motor end-limits have been commissioned
before adjusting the Axroll parameter settings.
Preset parameters
(in factory)
0:4
Operating parameters
Functioning mode: “SEQUENTIAL”
= 02
Security input for safety edge enabled when closing
the door
= 02
No accessory connected to security input 2
= 00
No accessory connected to security input 3
= 00
Safety action of the door upon closing (stop and then
total reopening of the door)
= 01
Self-test for accessory with TEST input
= 02
No self-test for security input 2
= 00
No self-test for security input 3
= 00
Auxiliary accessory
parametering
Contact to drive a zone lighting and an orange light
with integrated blinker (required if access giving on the
public highway).
= 04
Remote control
programming
Recording
remote controls
Press the remote control button to
program and the
button on the
Axroll simultaneously for 3 seconds
until dashes appear.
The control is now recorded.
3 sec.
Deleting the
remote controls
Delete all remote controls by
pressing and holding the
button
for 3 seconds until dashes appear.
All controls have been removed.