36
The first button "COMBUSTION”
, shows the options that can be set that affect
combustion: selected power, calibration of the pellet worm motor and calibration of
the smoke extractor speed.
Note: These functions allow the quantity of pellets
and the rpm of the extractor to be increased or reduced by up to 25% during
the start-up and power-up process.
- The second button "HEATING"
, serves to set the boiler temperature set, the
temperature of the inertia tank and the DHW tank,
note: only applies if the tank
probes are connected to the boiler.
- The third button "MANUAL LODING”
, button enables you to load pellets manually
and continuously for 10 minutes. This will be very useful for loading or filling the pellet
channel the first time you start the boiler or if, for some reason, the channel is empty.