![SOLZAIMA AMBER Instruction Manual Download Page 9](http://html.mh-extra.com/html/solzaima/amber/amber_instruction-manual_1317240009.webp)
9
2-
From the base of the equipment
If the installation of the air inlet kit is from the base of the equipment, you can choose from 2
installation zones, from the back of the base or from below the base as shown in Figure 8.
You must break the micro assemblies of the zone (M), using the option you chose to apply the kit.
Figure 8 - External air inlet, (M) section to be cleared for external air inlet
The external air inlet kit must be placed in the lower area of the equipment, as shown in Figure 9. To
do this, loosen the 3 screws that fix the base to the equipment and apply the external air inlet kit with
the 4 nuts that come in the package.
Figure 9 - Bottom view of the equipment, application of the external air inlet kit
3.2.3. Optional Modules
3.2.3.1. Firewood Base Door
If you want to put the door in the base of the equipment, you must purchase this accessory separately
and must follow the following steps.
Outdoor air inlet kit, from
the rear of the base.
Outdoor air inlet kit, from
the bottom of the base.
(M)
(M)
Loosen the 3 screws that fix the base to the equipment
Attachment of the external air inlet kit