background image

  This appliance can be used by children aged from 8 years and above and persons with reduced 

  physical, sensory or mental capabilities or lack of experience and knowledge if they have been 
  given instruction concerning use of the appliance in a safe way or are supervised and 
  understand the hazards involved.

  Children shall not play with the appliance.

  Cleaning and user maintenance shall not be carried out by children without supervision. 

  Children of less than 3 years should be kept away from the appliance unless continuously supervised. 

  Children aged from 3 years to 8 years shall only switch on/off the appliance provided that it 

  has been placed or installed in its intended normal operating position and they have been given 
  instruction concerning use of the appliance in a safe way or are supervised and understand the 
  hazards involved.

  Children aged over 3 and less than 8 years shall not plug in, regulate, clean nor maintain the 

  appliance.

  Children of any age should not be permitted to play with the appliance or its controls.

  If the supply cord is damaged, switch off the mains power at the wall socket immediately. It must 

  be replaced by the manufacturer, its service agent or a similarly qualified person in order to 
  avoid a hazard.

  Do not use the appliance in rooms with explosive gas (e.g. petrol) or while using inflammable glue 

  or solvent (e.g. when gluing or varnishing parquet floors, PVC etc.)

  Do not insert any objects into the appliance.

  This appliance must be connected to a 220/240V AC 50Hz supply.

04

Remote Control Battery Warning:

Only adults should handle the batteries. Do not allow a child to use the remote control unless the 
battery cover is securely attached to the battery compartment. All batteries must be disposed of 
at your local recycling point. 
Box Contents:
Please check that the following components are included within the box. If anything is missing or 
damaged, please contact the retailer and do not use the appliance until you have everything.

  Appliance with trailing kettle-type socket.

  Kettle-type lead with moulded 13 Amp plug.

  Remote control hand set.

  Stability/fixing system.

  Instruction manual.

Summary of Contents for SLE40i

Page 1: ...st be carried out in accordance with current Standards and Local Codes The instructions in this manual must be followed to ensure safe operation of the appliance It should be noted that the requiremen...

Page 2: ...d Brightness Operation Flame Brightness Operation Setting the Time and Day 24 Hour Clock Setting the Weekly Timer Thermal Safety Cut Out Light Emitting Diode Battery Replacement Remote Control Trouble...

Page 3: ...switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility CAUTION Some parts of this appliance around the heater grill can become very hot and ca...

Page 4: ...age should not be permitted to play with the appliance or its controls If the supply cord is damaged switch off the mains power at the wall socket immediately It must be replaced by the manufacturer...

Page 5: ...1 Read these instructions in conjunction with the instructions which came with the appliance itself 2 Chamber opening dimensions MIN 420mmWx570mmHx75mmD MAX440mmWx580mmHxNO MAX DEPTH 3 Open chimney f...

Page 6: ...eyelet 2 and bring the loose end back through the right hand hole 3 in the front of the appliance Thread again through hole 4 and bring the loose end back through the hole 5 Fig 7 5 Without damaging t...

Page 7: ...the back of the frame to hold it in place 3 Line up the frame and appliance by slightly moving to left or right Fig 8 Fig 8 Frame Style Two Trim Fret ensure the second canopy is in place 1 Unpack the...

Page 8: ...frame Fig 12 4 Hook the frame into the holes of bends Ensure that the hooks engage in the holes with the weight of the fireframe being borne by the floor or hearth Fig 13 Fig 14 Fig 15 5 Now fit the...

Page 9: ...No Heater 10W Motor Heater 12W Gross Weight kgs 10 5kg Efficiency Rating A Commissioning and Handover On completion of the installation Ensure that the operating instructions for the unit are left wi...

Page 10: ...utput elmax N A kW Type of heat output room temperature control select one At minimum heat output elmin N A kW single stage heat output and no room temperature control no In standby mode elSB 0 45 W T...

Page 11: ...ntrol only For the unit to operate the manual ON OFF switch located on the leftside of the switch panel must be switched to the I position Behind the screen a red light will illuminate when the fire i...

Page 12: ...above the room temperature for the heating function to operate Fig 23 Heater Operation Press the Heater button to select Full Heat 2000W and H02 with the flame symbol will be displayed see Fig 23 Pres...

Page 13: ...can also be adjusted by pressing the Brightness button to select from the following levels see Fig 26 H High Maximum Setting C Central Intermediate Setting L Low Minimum Setting NOTE Icon flashes on...

Page 14: ...on 2 Press and hold the Timer Mode button for two seconds to enter the timer settings 3 Press the Time Setting button to select the day to programme 4 The settings for the 1st ON OFF period 1 for Mon...

Page 15: ...or if an attempt is made to charge a battery not intended to be recharged Thermal Safety Cut Out A thermal safety cut out is incorporated in the heater to prevent damage due to overheating This can h...

Page 16: ...cking sounds and will occur when your heater fan and heating elements are switched on or off 2 Flame Effect To ensure you experience a slow and relaxed flame effect speed the electric motor provides i...

Page 17: ...an be ordered from www solutionfires co uk or directly from a Solution Fire Retailer Items considered as consumable such as glass screens bulbs LED boards ceramic logs fuses and batteries which are ei...

Page 18: ...9 Synchronous Motor 2203047 10 Blower and Heater Assembly 2203050 EXPLODED VIEW 15 NO DESCRIPTION PART NUMBER 1 2 3 4 5 6 7 8 Front Log Flame screen Power Supply Board Main PCB Board Fuel Bed LED Rot...

Page 19: ...Wiring Diagram 19...

Page 20: ...www solutionfires co uk I info solutionfires co uk Capital Fireplaces Units 12 17 Henlow Trading Est Henlow Bedfordshire SG16 6DS...

Reviews: