Inverter User Manual
Version 1.14, June 2020
10
10.- MAINTENANCE
The inverter does not require any special maintenance. Periodic cleaning of the
casing with a dry cloth is recommended. If necessary, a dampened cloth with soapy
water can be used (never dampen with alcohol or solvents).
11. – SAFETY
The inverter is reasonably protected against most of the possible causes of
damage. The following table shows the possible causes of disconnection and their
solutions.
FAILURE
RESULT
SOLUTION
Over-temperature
“Load Disconnection” and
“Overtemperature” LED alarms will turn
on.
Inverter automatically restarts (beware!)
when temperature reaches the normal
values.
Reverse Polarity
Inverter does nothing.
Connect the battery correctly.
Overload or short-circuit “Load Disconnection” and Shortcircuit”
(if applicable) LED alarms will turn on.
Turn OFF the inverter, eliminate the
cause of shortcircuit or overload, and
turn on the inverter again.
High Battery voltage
“Load Disconnection” and “High Battery
Voltage” LED alarms turn on.
Inverter automatically restarts (beware!)
when battery voltage drops to
reconnection voltage.
Low Battery voltage
“Load Disconnection” and “Low Battery
Voltage” LED alarms turn on.
Inverter automatically restarts (beware!)
when battery voltage rises to
reconnection voltage.
If you restart the inverter after a low battery voltage disconnection then the it will
work for a while before shutting down again. This is normal, because the battery is still
depleted. You must wait for the battery to recharge partially, and the best way to
achieve this is using the automatic restart feature of the inverter.