Do not place the electric fence in mires, marsh areas or places where the animal cannot

retreat.

Avoid placing the fence near areas where there is a risk of explosion, inflammable liquids,

etc. as small sparks from the fence links may provoke a fire.

In the case of storms it is advisable to disconnect the fence from the electric fencer and

from the electrical current.

We recommend placing signs to indicate the location of the electric fence.

Finally connect the electric fencer to the mains. If everything is in order, the equipment

should produce periodic electrical discharges.

With respect to battery-powered electric fencer, connect the red cable to the positive termi-

nal and the black cable to the negative battery terminal. Make sure a proper battery is

being used and it is completely charged.

For each discharge the pilot light up (Fig.1), if this does not occur it means that the fence is

losing charge through a grounded connection, disconnect the electric fencer from the elec-

trical power supply and check the fence.

For ECB-12 models, enusre that the terminal areas are free from branches, plants, etc. in

order to avoid discharges trough accidental contact.
POSSIBLE ANOMALIES AND SOLUTIONS

EXPLODED DIAGRAMS
ECB-12 V

ANOMALY

POSSIBLE CAUSE

The electric fencer

does not produce a

discharge

Check that the electric fencer is connected to the electrical power

supply and that the supply voltage is correct.
For battery-powered fencer ensure that the battery is charged and

that the terminals are connected properly.

Pilot light failure

With the electric fencer off, disconnect the fence cables and recon-

nect the electric fencer. If the pilot light no lights up on each dis-

charge, the problem is to be found in the fence. Check the insulation

in the entire fence, dividing it if necessary.
Check that there is power on the output terminals, use an insulated

screwdriver to touch a terminal and move it half a centimeter from

the other terminal, if everything is in the correct position, discharges

should happen every second.

SOLTER 

SOLDADURA S.L.

2

Description

Code

1

Potentiometer

73102

2

Negative terminal

89304

3

Positive terminal

89303

4

Condenser

89103

5

Control circuit

89100

6

High voltage transformer

-

7

On indicator

77500

8

Low battery indicator

77500

9

Fence fault indicator

77500

Summary of Contents for ECB-12

Page 1: ...ONES INSTRUCCIONES PARA EL USO Y EL MANTENIMIENTO LEA ESTE MANUAL ANTES DE PONER EN MARCHA EL EQUIPO MI03006 00 INSTRUCTIONS FOR THE USE AND MAINTENANCE READ THIS MANUAL BEFORE STARTING THE EQUIPMENT...

Page 2: ...zarlo SOLTER SOLDADURA S L declina toda responsabilidad por pr cticas negligentes en la utilizaci n y o manipulaci n Este manual debe adjuntarse y conservarse con el modelo de m quina adquirido DECLAR...

Page 3: ...l cercado Para modelos ECB 12 assegurarse de que la zona de los terminales este libre de ramas vegetales etc para evitar descargas inecessarias por cruce de los mismos POSIBLES ANOMAL AS Y SOLUCIONES...

Page 4: ...ienda desencarar un poco la placa del sol MONTAJE DE LOS ELECTRIFICADORES Para conseguir un cercado correctamente instalado se recomienda utilizar aisladores de m xima calidad de otro modo se pueden p...

Page 5: ...el electrificador a la cerca Se conectar el borne de tierra negro con una piqueta de 2 m de longitud al suelo Si el terreno es muy seco humedecerlo de vez en cuando e incrementar el n mero de piqueta...

Page 6: ...dos los clientes propietarios de equipos SOLTER ATENCI N CLIENTE 902 43 12 19 Email solter solter com En caso de aver a o consulta t cnica no dude en ponerse en contacto con nosotros y nuestro equipo...

Page 7: ...t be kept with the equipment purchased EC DECLARATION OF CONFORMITY EC COMMUNITY REGULATION 89 336 EEC ON EMC MACHINES AND EC REGULATION 73 23 EEC ON LOW VOLTAGE MACHINERY Those persons who use and re...

Page 8: ...re that the terminal areas are free from branches plants etc in order to avoid discharges trough accidental contact POSSIBLE ANOMALIES AND SOLUTIONS EXPLODED DIAGRAMS ECB 12 V ANOMALY POSSIBLE CAUSE T...

Page 9: ...many hours of sunlight we recommend mo ving the solar panel so that it does not directly face the sun ASSEMBLING THE ELECTRIC FENCER To install the fence correctly we recommend using high quality ins...

Page 10: ...o the fence Connect the black earth terminal using a 2m lenght rod placed in the ground If the ground is dry wet it from time to time and increase the number of earthing rods at a distance of every 2...

Page 11: ...olter solter com All purchases of SOLTER equipment will enjoy the advantages of SOLTER exclusive tech nical assistance In case of breakdown or technical questions contact us and our team will be pleas...

Page 12: ...enummer ALL THE UNITS MANUFACTURED SINCE To which this declaration relates is in conformity with the following standard s or other normative document s Al que se refiere esta declaraci n est en confor...

Page 13: ...del equipo disfrutar en cada momento de todos los derechos que la normativa vi gente conceda La garant a no cubre aver as debidas a un mal uso mal trato o deterioro accidental as como aquellos aparat...

Reviews: