INDICE
INTRODUCTION .............................................................................................................1
TECHNICAL CHARACTERISTICS .................................................................................1
CAUTIONS ......................................................................................................................1
POSSIBLE ANOMALIES AND SOLUTIONS...................................................................2
EXPLODED DIAGRAMS.................................................................................................2
ASSEMBLING THE SOLAR PANEL ...............................................................................3
ASSEMBLING THE ELECTRIC FENCER.......................................................................4
EXAMPLES OF FENCES................................................................................................4
SOLTER TECHNICAL ASSISTANCE..............................................................................5
OFFICIAL APROVALS.....................................................................................................A1
DECLARATION OF GUARANTEE..................................................................................A2
INTRODUCTION
Thank you for purchasing this equipment, we hope this electric fencer will serve you well
and fulfil your expectations.
This instruction manual has the information and warnings necessary for correct use within
the maximum conditions of operator safety.
If you have any queries or doubts regarding this manual, please feel free to contact us.
Internal handling of the equipment may result in a serious electric shock. Avoid opening or
working inside the equipment. Only technically trained personnel should perform these
tasks.
SOLTER SOLDADURA, S.L
. cannot be held responsible for negligent practices in equip-
ment use and/or handling.
This manual must be kept with the equipment purchased.
EC DECLARATION OF CONFORMITY. EC COMMUNITY REGULATION 89/336/EEC ON
EMC MACHINES AND EC REGULATION 73/23/EEC ON LOW VOLTAGE MACHINERY.
Those persons who use and repair the equipment are responsible for ensuring that the
product continues to fulfil the requirements of the abovementined regulations.
SOLTER electric fencer are manufactured without moving parts and are totally electronic.
All components are protected from moisture and corrosion by an encapsulation of specially
developed resin.
TECHNICAL CHARACTERISTICS
CAUTIONS
The use of this equipment does not involve any danger. The electric discharges last for
short period followed by long pauses so that the animal can retreat.
Always connect the equipment to the voltage indicated.
Do not open the electric fencer with the power connected, this may result in shocks.
ECB–12
ECE–25
ECE–50 ECE–100 ECE–150
Power supply
12V DC
230 ±10% 230 ±10% 230 ±10% 230 ±10%
Input power
1,5 W
2 W
5 W
10 W
12 W
Maximum enclosure(fence)
25 Km
10 Km
50 Km
100 Km
150 Km
Vacuum discharge voltage
10.000V
Pulse duration
200 ms
Pulse interval
>1 seg.