background image

 

The areas near both newly installed fences and fence areas wich have been electrified

for a time must be cleaned and freed from plants wich may touch the cable.

Once the fence is clear, ECE-100 or ECE-150 equipment will ensure that the plants do not

grow near the fence. Less powerful electric fencers require periodical claering of the near

by area.

 

Connect the electric fencer to the fence. Connect the black earth terminal using a 2m

lenght rod placed in the ground. If the ground is dry, wet it from time to time and increase

the number of earthing rods at a distance of every 2 meters. The other red terminal must

be connected to the fence in order to ensure effective electric contact.

ECB-12

ECE-25 / ECE-50 / ECE 100 / ECE 150

EXAMPLES OF FENCES

SOLTER 

SOLDADURA S.L.

4

Division fence for cattle

Outdoor fence for cattle on dry land with

anti-intrusion feature.

Outdoor fence for sheep

Wild boar for protection or outdoor fence for

pigs

Outdoor fence for horses

Summary of Contents for ECB-12

Page 1: ...ONES INSTRUCCIONES PARA EL USO Y EL MANTENIMIENTO LEA ESTE MANUAL ANTES DE PONER EN MARCHA EL EQUIPO MI03006 00 INSTRUCTIONS FOR THE USE AND MAINTENANCE READ THIS MANUAL BEFORE STARTING THE EQUIPMENT...

Page 2: ...zarlo SOLTER SOLDADURA S L declina toda responsabilidad por pr cticas negligentes en la utilizaci n y o manipulaci n Este manual debe adjuntarse y conservarse con el modelo de m quina adquirido DECLAR...

Page 3: ...l cercado Para modelos ECB 12 assegurarse de que la zona de los terminales este libre de ramas vegetales etc para evitar descargas inecessarias por cruce de los mismos POSIBLES ANOMAL AS Y SOLUCIONES...

Page 4: ...ienda desencarar un poco la placa del sol MONTAJE DE LOS ELECTRIFICADORES Para conseguir un cercado correctamente instalado se recomienda utilizar aisladores de m xima calidad de otro modo se pueden p...

Page 5: ...el electrificador a la cerca Se conectar el borne de tierra negro con una piqueta de 2 m de longitud al suelo Si el terreno es muy seco humedecerlo de vez en cuando e incrementar el n mero de piqueta...

Page 6: ...dos los clientes propietarios de equipos SOLTER ATENCI N CLIENTE 902 43 12 19 Email solter solter com En caso de aver a o consulta t cnica no dude en ponerse en contacto con nosotros y nuestro equipo...

Page 7: ...t be kept with the equipment purchased EC DECLARATION OF CONFORMITY EC COMMUNITY REGULATION 89 336 EEC ON EMC MACHINES AND EC REGULATION 73 23 EEC ON LOW VOLTAGE MACHINERY Those persons who use and re...

Page 8: ...re that the terminal areas are free from branches plants etc in order to avoid discharges trough accidental contact POSSIBLE ANOMALIES AND SOLUTIONS EXPLODED DIAGRAMS ECB 12 V ANOMALY POSSIBLE CAUSE T...

Page 9: ...many hours of sunlight we recommend mo ving the solar panel so that it does not directly face the sun ASSEMBLING THE ELECTRIC FENCER To install the fence correctly we recommend using high quality ins...

Page 10: ...o the fence Connect the black earth terminal using a 2m lenght rod placed in the ground If the ground is dry wet it from time to time and increase the number of earthing rods at a distance of every 2...

Page 11: ...olter solter com All purchases of SOLTER equipment will enjoy the advantages of SOLTER exclusive tech nical assistance In case of breakdown or technical questions contact us and our team will be pleas...

Page 12: ...enummer ALL THE UNITS MANUFACTURED SINCE To which this declaration relates is in conformity with the following standard s or other normative document s Al que se refiere esta declaraci n est en confor...

Page 13: ...del equipo disfrutar en cada momento de todos los derechos que la normativa vi gente conceda La garant a no cubre aver as debidas a un mal uso mal trato o deterioro accidental as como aquellos aparat...