SPECIAL FEATURES
Special features can be accessed through the
FnP
menu option.
ATTENTION
Changing advanced parameters can significantly alter the correct operation of the machine. Change
these settings at your own risk. If you notice the machine is operating irregularly, reset the parameters
to their default values, or select the "ini" menu option to reset all operating parameters and settings to
the factory settings.
Function
Default value
Description
P.01
-
Not available in this model.
P.02
-
Not available in this model.
P.03
OFF
ON - Enables remote MMA setting mode. See P.23 and P.24.
OFF - Local control.
P.04
OFF
ON - Enables amperage reduction system by increasing the arc height for MMA wel-
ding processes.
OFF - Disabled.
P.05
-
Not available in this model.
P.06
OFF
ON - Enables remote control for Aerofeed unit.
OFF - Local control in power unit.
P.07
OFF
ON - Enables pilot arc ignition in TIG mode.
OFF- Normal ignition.
P.08
ON
ON - Enables display of average welding voltage at the end of the bead.
OFF -Disabled.
P.09
-
Not available in this model.
P.10
Normal
Allows you to select the type of main button in TIG mode; normal for open or inverted
for closed.
P.11
-
Not available in this model.
P.12
-
Not available in this model.
P.13
Normal
Allows you to select the type of main button in MIG mode; normal for open or inver-
ted for closed.
P.14
Normal
Allows you to invert the minimum and maximum position of the remote potentiometer
of the TIG torch or of the remote control for MMA mode.
P.15
-
Not available in this model.
P.16
-
Not available in this model.
P.17
4
Torch length in meters. Allows the compensation of voltage reading.
P.18
50
Cable section in torch, in mm
2
. Allows the compensation of the voltage reading.
P.19
2
Length of connection between power unit and winder, in meters.
P.20
70
Cable section of connection between power unit and winder, in mm
2
.
P.21
3
Length of earth lead in meters. Allows the compensation of the voltage reading.
P.22
50
Section of earth lead in mm2. Allows the compensation of the voltage reading.
P.23
10
Minimum amperage setting in remote MMA mode. See P.03
P.24
420
Maximum amperage setting in remote MMA mode. See P.03
P.25
-
Not available in this model.
P.26
-
Not available in this model.
SOLTER
SOLDADURA S.L.
AEROPROCESS
19