![Solon VASCO Solar 212 Installation And Operating Manual Download Page 5](http://html.mh-extra.com/html/solon/vasco-solar-212/vasco-solar-212_installation-and-operating-manual_1316618005.webp)
5
3. Technical Characteristics
Model
Vin
Vin
P1 nom*
Max Vout
Max I out
Typical motor P2
[VDC]
[VDC]
[VAC]
[A]
[VAC]
[kW]
VASCO Solar 212
120 – 650
> 320
3 x 230
12
3 x 230
2,2
VASCO Solar 409
320 – 850
> 560
3 x 400
9
3 x 400
3
VASCO Solar 412
320 – 850
> 560
3 x 400
12
3 x 400
4
VASCO Solar 415
320 – 850
> 560
3 x 400
15
3 x 400
5,5
VASCO Solar 418
320 – 850
> 560
3 x 400
18
3 x 400
7,5
VASCO Solar 425
320 – 850
> 560
3 x 400
25
3 x 400
11
VASCO Solar 430
320 – 850
> 560
3 x 400
30
3 x 400
15
x
Max ambient temperature at nominal current: 50°C (122 °F)
x
Max. altitude at nominal current: 1000 m
x
Grade of protection: IP65 (NEMA 4)*
x
RS485 serial communication
x
PWM configurable: 2.5 ,4, 6, 8, 10 kHz
* avoid direct exposition to solar rays.
VASCO Solar Solar is able to power the motor with a higher current for a short period of time according to the linear
relation: 101% of the nominal current for 10min., 110% nominal current for 1 min.
3.1 Weight and dimensions
Model
Weight
*
[Kg]
VASCO Solar 212
8,2
VASCO Solar 409
8,3
VASCO Solar 412
8,5
VASCO Solar 415
8,5
VASCO Solar 418
8,7
VASCO Solar 425
8,7
VASCO Solar 430
8,7
* Weight without packing.