1-5
Parameter
Specification
Warning features
Over-voltage, over-current, over-
temperature, reverse polarity
PV connector
Staubli MC4-EVO2
Weight
4
6.6 kg (including soft case, test leads &
charger)
Height
38 cm (not including primary PV leads)
Width
20 cm (not including handle)
Depth
13 cm (not including gear pouch)
1
Conventional PV modules and strings may be measured in parallel, up to the current
limit specified here. High-efficiency modules should NOT be measured in parallel.
2
Time between pressing "Measure Now" and display of measurement result.
3
Automatically selected. Measurement sweep time depends upon the characteristics of
the test device (PV module, string, or array) electrical characteristics.
4
The measurement is controlled via wireless link from the user's tablet or notebook PC.
PVA-1500xx Test Lead and Clip Specifications
Table 2. Electrical and mechanical specifications for the test leads and clips provided
with the PVA-1500xx.*
Parameter
Specification
Voltage range
0
– 1500 V DC
Current range
0
– 30 A DC
Temperature
5 °C to 40 °C
Humidity
Maximum relative humidity of 80 % for
temperatures up to 31 °C decreasing linearly to
50 % relative humidity at 40 °C
Pollution degree
2
Altitude
Up to 2000 m
Lead length
152 cm
Lead colors
Positive = red, negative = black
Manufacturer (test leads and Dolphin clips)
Staubli
Summary of Contents for PVA-1000S