SIG-5600 User Manual Ver. 1.0
- 9 -
1.4.7
Digital Output Port
This port is interfaced with a 5mm pitch 12-pole terminal block.
Figure 1-5 Digital output port
⚫
Port Specification
Division
Value
Number of ports
2
Max. Allowed Current
at DC 30V
Normal Open
5A
Normal Close
1A
Table 1-3 Port Specification
The port specifications are for resistive loads. It is recommended to design with
a margin of about 10 ~ 20% of the maximum allowable current for capacitive loads
such as SMPS and inductive loads such as motors.
⚫
Port Operation
Division
NO Operation
NC Operation
OFF
NOT connected to COM
Connected to COM
ON
Connected to COM
NOT connected to COM
Table 1-4 Port Operation