7.4
Additional Functions
7.4.1 Factory Reset
It is a function physically initializes all the values. Users can set customized default for the
factory reset. However, if you don’t set the default, it will be initialized to the factory default.
Using Factory Reset
① Connect pin #12(CONFIG#) of CON1 to GND (input LOW signal)
② Connect pin #3 of CON1 to GND (input LOW signal over 3 seconds)
③ Factory Reset will be automatically implemented to default values.
④ Disconnect the two pins from GND
⑤ Reboot
Setting custom default values
① Change the mode to Serial Configuration
② Save custom default values by ezManager or serial configuration commands
③ Input the command below
b
<SPACE>
3c5a
<CR>
④ After that, current values in the SRAM will be used for Factory Reset.