SOLIS S6-EH1P10K-H-US Product Manual Download Page 46

Rated output power

7.6kW

6kW

Max. apparent output power

12.2 kVA, 10 sec

9.6 kVA, 10 sec

AC Output (Backup and Off-grid)       

Max. output current for 10 seconds

PV Max. efficiency 

PV CEC efficiency 

BAT charged by PV Max. efficiency 

BAT charged/discharged to AC Max. efficiency 

97.6%

97.2%

98.5%

97.0%

Rated AC output current (continuous)

25A

40A

Max. allowable phase imbalance

Backup support configurations

Power Factor

THDv(@linear load)

100%

Dedicated loads and whole-home (with a Solis Power Hub) 

>

0.99 (0.8 leading - 0.8 lagging)

<3%

Efficiency

Protection    

Ground fault detection

Residual (leakage) current detection

Integrated AFCI (DC arc-fault circuit protection)

DC reverse-polarity protection

Rapid Shutdown NEC 2017

Compatible RSD Receivers

Protection class/Over voltage category

Yes (PV only)

Integrated SunSpec-certified Transmitter

See MLRSD compatibility sheet

I/II

Rated grid frequency

Max. output current for 300 milliseconds

60 Hz

Rated output voltage(L1-L2)/(L1/L2-N)

AC output voltage range

240 V/120 V

204-276 V

Back-up switch time

Phase Power

10 ms

240V Split-Phase

31.7A

50.7A

Yes

Yes

Yes

Technical Data

S6-EH1P6K-H-US

S6-EH1P7.6K-H-S-US

42

7. Specifications

45A

57.06A

Summary of Contents for S6-EH1P10K-H-US

Page 1: ...Voltage Hybrid Single Phase Residential Energy Storage Inverter Version 2 4 Release Date 12 02 2022 Available Models S6 EH1P3 8K H US S6 EH1P5K H US S6 EH1P7 6K H S US S6 EH1P7 6K H L US S6 EH1P10K H...

Page 2: ...e customer is fully liable for any modifications made to the system therefore any hardware or software modification manipulation or alteration not expressly approved by the manufacturer shall result i...

Page 3: ...8 Appendix 7 Specifications 6 Troubleshooting 5 Commissioning 4 Installation 3 Overview 2 Safety 1 Introduction Table of Contents...

Page 4: ...4 1 Select a Location to Install the Inverter 4 2 Product Handling 4 3 Mounting the Inverter 4 4 Inverter Wiring Overview 4 5 External Grounding 4 6 PV Cable Installation 4 7 Rapid Shutdown 4 8 Batte...

Page 5: ...e Solis S6 hybrid inverter series consists of the following models 3 8kW 5kW 7 6kW 10kW and 11 4kW S6 EH1P7 6K H US has three MPPTs and S6 EH1P7 6K H US S L has four MPPTs The inverter comes equipped...

Page 6: ...ction DC Disconnect Switch Solis Data Logger sold separately Figure 1 4 Left Side View Mounting Bracket Hook AC Bypass Switch Rapid Shutdown Initiation Switch Solis Data Logger sold separately DC Cond...

Page 7: ...Solis service team External Energy Meter x1 Current Transformers x2 Ring Terminals x8 Terminal Pins x20 Torqx T20 Tool x1 1 Introduction 1 3 Tools Required for Installation Technician Screwdriver Tor...

Page 8: ...y examined and tested by qualified service or electrical personnel before using Restarting after a long period of non use requires the equipment be inspected and in some cases the removal of oxidation...

Page 9: ...on of your product 2 2 General Safety Instructions WARNING Electrical installations must be done in accordance with local and national electrical safety standards WARNING Do not connect PV array posit...

Page 10: ...rs that comply with the NEC Article 690 Part II All Solis single phase inverters feature an integrated DC disconnect switch CAUTION Risk of electric shock do not remove the cover There are no servicea...

Page 11: ...with protective circuitry and controls These include Arc Fault Circuit Interrupter AFCI and Anti Islanding Protection Arc Fault Circuit Interrupter AFCI Edition 2011 of the National Electrical Code Se...

Page 12: ...The Inverter indicator will remain on with lower brightness Short press the Inverter indicator to wake up the other indicators Light Status Description Blue Flashing every 3s Blue Flashing every 1 5s...

Page 13: ...C conductors to backup loads panel should be connected here Conduit for AC conductors to the main service panel should be connected here Extends the range of the inverter Bluetooth signal RS 485 and C...

Page 14: ...to install the inverter somewhere the rain and snow will not land directly on it The ideal installation location is on a north facing wall under an eave WARNING Risk of fire Despite careful installat...

Page 15: ...eful construction electrical devices can cause fires Do not install the inverter in areas containing highly flammable materials or gases Keep the inverter out of reach of children if children may be p...

Page 16: ...low around the inverter is not blocked Please review the instruction below for handling the inverter 1 The red circles below denote cutouts on the product package Push in the cutouts to form handles f...

Page 17: ...NOTE Nothing should be stored on top of or placed against the inverter The inverter must be mounted vertically with a maximum incline of 5 degree Exceeding this may cause the output power to derate Fi...

Page 18: ...d vertically All fasteners must embed in a wall stud unless you are using the provided expansion bolts on a concrete or brick wall Once a suitable location has been found according to 4 2 and 4 3 use...

Page 19: ...the inverter hooks down onto the mounting bracket tabs and ensure the hooks have a solid bite before releasing the inverter Then install the two stabilizing bolts that are included with the inverter s...

Page 20: ...e 4 2 2 Installing the energy meter From battery to terminal CAN L and CAN H For more details refer to figure 4 2 3 Installing the battery USB COM port at the bottom of the inverter For more details p...

Page 21: ...r solid conductor or stranded wire is acceptable Refer to local code standard for wire sizing 2 Strip the ground cable insulation to a suitable length see Figure 4 7 To connect the grounding terminal...

Page 22: ...string current If the current is above 0 5A please wait for the irradiance on the PV array to diminish until the current drops below 0 5A Once the current is below 0 5A you are allowed to open the DC...

Page 23: ...down transmitter This transmitter brand must match the receivers that are being installed with the PV modules Not abiding by this will void the inverter warranty Figure 4 13 Rapid shutdown initiation...

Page 24: ...able connection Model Table 4 2 Battery cable torque requirements S6 EH1P 3 8 7 6 K H S S6 EH1P 7 6 11 4 K H L OT Terminal Torque Note The battery fuse in the inverter wire box is replaceable The repl...

Page 25: ...supply is limited max of 47 5A for the 11 4kW model and 2 anything that draws a high amount of current will quickly drain the battery out which is not ideal 4 Installation Note A battery is required f...

Page 26: ...R type connectors onto the ends 3 Remove the terminal bolts insert them into the connectors then use a torque wrench to tighten the bolts down Follow the torque specifications in table 4 3 above 3 Pl...

Page 27: ...6 7A 47 5A 76A Note The L1 and L2 cables going from the B L1 and B L2 terminals of the inverter should terminate in an OCPD and not directly in the panel lugs AC Bypass Switch This switch determines t...

Page 28: ...in order to have full functionality of the hybrid inverter Used for CAN communication between the inverter and a compatible battery Used for RS485 communication with compatible batteries that use RS...

Page 29: ...ack up L1 L2 PE Critical Load 240V L1 L2 120V L1 N or L2 N L1 L2 N L1 PE L2 L1 N PE 240V Load 120V Load CT direction towards to grid N L1 L2 PE Grid CT1 CT2 N Grid Note COM1 and COM2 conduit knockouts...

Page 30: ...d The detailed connection is shown in the following figure Figure 4 19 LG Battery Communication S6 EH1P 3 8 11 4 K H US Note Some alarm codes are being relayed from the battery These alarms are caused...

Page 31: ...er The logger plugs into the COM port and then can be added to SolisCloud The Solis data loggers are optional and they can be purchased separately A dust cover is provided with the inverter in case a...

Page 32: ...e string Step 2 Turn on the OCPD for the system and then measure the AC voltages line to line and line to neutral The backup side of the system will be off until commissioning is complete Turn the OCP...

Page 33: ...uetooth devices Then tap BR2262e S note if this device does not appear be sure the inverter is at least getting start up DC voltage The next screen will prompt you to enter a password Enter the passwo...

Page 34: ...codes C Meter Setting Set both the Meter Type and the Meter Location For US installations thiswill be Acrel 1P Meter for the type and Meter in Grid for the location D Grid Code Systems in the US shou...

Page 35: ...the battery does not drain past the Reserve SOC state of charge percentage The battery will cycle between 100 and the Reserve SOC so if grid power is lost the battery will have the Reserve SOC at the...

Page 36: ...battery model and status battery voltage and current Battery power imported and exported AC grid voltage frequency and amperage Grid power being consumed by the home loads and backup loads Load There...

Page 37: ...tch will mean that the inverter will not produce any PV power if the inverter loses communication with the Acrel energy meter Tap Backup Setting and then tap Backup Port Reference Voltage Setting Ente...

Page 38: ...p 2 Turn off the DC switch of the inverter and push in the Rapid Shutdown Initiation Switch Step 3 Turn off the battery breaker Step 4 Use a multimeter to verify that the battery and AC voltages are 0...

Page 39: ...ntact installer DC INTF IGFOL F Grid current tracking fail IG AD Grid current sampling fail DSP B FAULT Comm failure between main and slave DSP ILeak PRO 01 02 03 04 DCinj FAULT leakage current protec...

Page 40: ...I OV IgTr OV ILLC OV TEM OV Vbatt1 OV Vbatt H Over Load OV VBackup Over Temperature The detection of battery overvoltage Battery overvoltage hardware fault Backup overload fault Backup overvoltage fau...

Page 41: ...r sales service We recommend gathering the following information before making contact in order to get a quicker resolution Item Inverter serial number SN Inverter Firmware Version Alarm history DC vo...

Page 42: ...er of batteries per inverter Technical Data S6 EH1P3 8K H US 6 080W 80V 80 550V 2 1 16A CAN RS485 See Battery Compatibility Sheet 3 8kW 3 8kW 15 8A 600V 120 500V Battery type Lithium ion Maximum charg...

Page 43: ...99 0 8 leading 0 8 lagging 3 Efficiency Protection Ground fault detection Residual leakage current detection Integrated AFCI DC arc fault protection DC reverse polarity protection Rapid Shutdown NEC...

Page 44: ...se emission Typical Natural convection Cooling method Features AC connection Monitoring Platform Communication Warranty SolisCloud modbus map and API sharing available upon request RS485 Optional Cell...

Page 45: ...nverter Technical Data S6 EH1P6K H US 9 600W 80V 80 550V 3 1 16A CAN RS485 See Battery Compatibility Sheet 6kW 6kW 25 0A 3 600V 120 500V Battery type Lithium ion Maximum charge discharge current 25A S...

Page 46: ...0 99 0 8 leading 0 8 lagging 3 Efficiency Protection Ground fault detection Residual leakage current detection Integrated AFCI DC arc fault circuit protection DC reverse polarity protection Rapid Shu...

Page 47: ...bus map and API sharing available upon request RS485 Optional Cellular Wi Fi LAN 10 years standard Extendable to 20 years Interface LED indicator lights Bluetooth Phone app 1 in knockouts for conduit...

Page 48: ...nverter Technical Data S6 EH1P7 6K H L US 12160W 80V 80 550V 4 1 16A CAN RS485 See Battery Compatibility Sheet 7 6kW 7 6kW 31 7A 600V 120 500V Battery type Lithium ion Maximum charge discharge current...

Page 49: ...lagging 3 Efficiency Protection Ground fault detection Residual leakage current detection Integrated AFCI DC arc fault protection DC reverse polarity protection Rapid Shutdown NEC 2017 Compatible Rap...

Page 50: ...available upon request RS485 Optional Cellular Wi Fi LAN 10 years standard Extendable to 20 years Interface LED indicator lights Bluetooth Phone app 1 in knockouts for conduit x2 on the side and botto...

Page 51: ...nverter Technical Data S6 EH1P10K H US 16 000W 80V 80 550V 4 1 16A CAN RS485 See Battery Compatibility Sheet 10kW 10kW 41 7A 600V 120 500V Battery type Lithium ion Maximum charge discharge current 50A...

Page 52: ...eading 0 8 lagging 3 Efficiency Protection Ground fault detection Residual leakage current detection Integrated AFCI DC arc fault protection DC reverse polarity protection Rapid Shutdown NEC 2017 Comp...

Page 53: ...ailable upon request RS485 Optional Cellular Wi Fi LAN 10 years standard Extendable to 20 years Interface LED indicator lights Bluetooth Phone app 1 in knockouts for conduit x2 on the side and bottom...

Page 54: ...50 8 1 Appendix Single Line Diagrams Single Line Diagram 1 One hybrid inverter...

Page 55: ...51 8 1 Appendix Single Line Diagrams Single Line Diagram 2 Two hybrid inverters in parallel...

Page 56: ...ttings changes and firmware updates Q6 What is the Solis Power Hub mentioned in the video and will that launch at the same time as the new S6 hybrid inverter A6 The Solis Power Hub is a microgrid inte...

Page 57: ...orage modes will the S6 hybrid offer A12 The S6 hybrid has multiple modes For every mode the first priority of the system is to support the home loads makes the second priority charging the battery wi...

Page 58: ...8 3 Appendix Derating Curves 54 8 3 1 Temperature Derating Curve...

Page 59: ...8408 If you encounter any problems with the inverter please take note of the inverter serial number and then contact us using the phone number or email listed above Compliant with CA Rule 21 HECO Rul...