5. Operation

5. Operation

5.5.2 Running Message

5.5.3 Version

Inverter model number and software version can be viewed in this section.

Values are for reference only..

This function is for maintenance person to get running message such as internal 

temperature, Standard NO. etc.(Values are for reference only.).  

Settings

Figure 5.15 Running Message

Running

 

Message

2015-02-23   19 35

DC

 

Bus

 

Voltage

Reactive

 

Power

 

Ratio

Output

 

Power

 

Limit

Control

 

Word

 

Status

Inverter

 

Temperature

Standard

410.7V
+1.00
100%
0000H
+0031.6degC
G59/3

E S C

Grid Filter NO.

00

Ground Voltage

000.0V

版本号

2015-02-23   19 35

Version

2015-02-23   19 35

Model

Software

 

Ver.

F8
140000

E S C

Figure 5.16 Model Version and Software Version

Battery Enable

Disable

5.5.5 Daily Energy

Figure 5.18 Daily Energy

Daily

 

Energy

2015-02-23   19 35

2 0 1 5

-

-

2 3

0 2

0 0

1 0

2 0

3 0

4 0

5 0

6 0

D

a

il

y E

n

e

r

g

y

[k

W

]

0 0 : 0 0

0 3 : 0 0

0 6 : 0 0

0 9 : 0 0

1 2 : 0 0

1 5 : 0 0

1 8 : 0 0

2 1 : 0 0

0 0 : 0 0

E S C

U P

D O W N

E N T

The screen shows the daily energy detail of the inverter.

5.5.4  Communication Data

Internal communication data can be viewed in this section. For maintenance person only.

Values are for reference only.

Figure 5.17 Communication Data

Communication Data

2015-02-23   19 35

01

-

10

11

-

20

21

-

30

31

-

40

41

-

50

51

-

60

61

-

70

71

-

80

81

-

90

86 61 A1 00 01 50 8A 06 1E 00

D5 05 1E 00 00 00 00 00 00 00

00 00 00 00 00 00 00 00 00 00
09 02 00 00 00 00 B8 10 C0 00
20 5C 80 01 00 00 43 00 07 02
01 00 04 00 6D 04 E6 05 01 00

DC 05 1E 00 59 06 1E 00 D4 03
10 27 00 00 00 00 00 00 00 00

00 00 00 00 00 00 60 00 00 00

E S C

.33.

.32.

Summary of Contents for S5-EH1P3.6K-L

Page 1: ...315712 P R China Tel 86 0 574 6578 1806 Fax 86 0 574 6578 1606 If you encounter any problem on the inverter please find out the inverter S N and contact us we will try to respond to your question ASA...

Page 2: ...able Assembly Contents 4 2 3 Notice For Use 6 3 3 Terminal Connection 21 4 11 Inverter monitoring connection 13 4 4 Battery Input Connection 19 4 8 External ground connection 20 4 9 DRED port connecti...

Page 3: ...ckup terminal x1 Display Key Connector x1 CAN cable x1 Battery Cable x2 Rs485 Meter cable x1 For Acrel Meter Rs485 Meter cable x1 For Eastron Meter The Solis S5 EH1P L Series is designed for residenti...

Page 4: ...UTION Risk of electric shock from energy stored in capacitors of the Inverter do not remove cover for 5 minutes after disconnecting all power sources service technician only Warranty may be voided if...

Page 5: ...ter must be installed according to the instructions stated in this manual 4 The inverter must be installed according to the correct technical specifications 6 7 3 2 Keypad There are four keys in the f...

Page 6: ...he LEDs and LCD should be considered Adequate ventilation must be provided NOTE Nothing should be stored on or placed against the inverter Install vertically with a maximum incline of 5 degrees exceed...

Page 7: ...4 5 Wall Mount Bracket WARNING The inverter must be mounted vertically 2 Lift up the inverter be careful to avoid body strain and align the back bracket on the inverter with the convex section of the...

Page 8: ...please carefully read the user manual of the battery and perform the installation exactly as the battery manufacturer requests 4 3 PV Input Connection Please ensure the following before connecting the...

Page 9: ...sure Length Numerical value There are two AC terminals and the assembly steps for both are the same Take out the AC connector parts from the packaging 4 Push Housing into Body 6 The same installation...

Page 10: ...ther market exclude Italy Below 4 6 2 section describes the connection diagram of the Eastron 1ph meter Direct Insert Standard Accessory for Italian market 4 6 1 Single phase meter installation Power...

Page 11: ...gative pole at the other side BTS is optional For further information please contact the sales manager For lead acid battery battery SOC calculation may not be accurate according to battery inconformi...

Page 12: ...steps to assemble RJ45 connector 1 Insert the network cable into the communication connection terminal of RJ45 Figure 4 18 RJ45 communication connection terminals 3 Connect RJ45 to DRM port Figure 4 1...

Page 13: ...ill show up on the LCD screen Inverter should be installed in a high traffic area to ensure the alarm to be noticed The inverter can t start to generate until the earth fault is resolved Please refer...

Page 14: ...hown above the arrow Battery When the battery is connected successfully it will display CAN OK meanwhile battery SOC arrow and value of power ow is shown Otherwise it will display CAN Fail Non Critica...

Page 15: ...ge2 Grid Voltage Battery Voltage Backup Voltage Solar Current1 Solar Current2 Grid Power Grid Frequency 02890W 345 1V 354 3V 221 5V 050 6V 000 0V 4 2A 4 1A 02259W 50Hz ESC UP DOWN ENT DRM NO 08 Charg...

Page 16: ...Meter is only available when two Eastron meters are used and Meter Placement is selected as Grid PV Meter Details please consult Solis service department 5 4 Settings In the Settings section Time Dat...

Page 17: ...Communication Data 5 Daily Energy 6 Monthly Energy 7 Yearly Energy 8 Total Energy 9 Warning Message 10 Inspection Figure 5 13 Advanced Information Settings Advanced Information 2015 02 23 19 35 Warni...

Page 18: ...Version and Software Version Battery Enable Disable 5 5 5 Daily Energy Figure 5 18 Daily Energy Daily Energy 2015 02 23 19 35 2015 23 02 00 10 20 30 40 50 60 D a i l y E n e r g y k W 00 00 03 00 06 0...

Page 19: ...3 0 Ye a r l y E n e r g y M W h 01 02 03 04 05 06 07 08 09 10 11 12 00 51 ESC UP DOWN ENT Figure 5 20 Yearly Energy Settings Warning Message 2015 02 23 19 35 Message Date Time Data NO message ESC UP...

Page 20: ...ard 4777_A 4777_B 4777_C and 4777_N for compliance with AS NZS4777 2 2020 The standard AS4777 15 is for AS NZS4777 2 2015 The default password is 0010 Please press down to move the cursor press up to...

Page 21: ...600S 230 276V 50 52Hz 1 2S 0 1 2S 10 11S 1 2S 0 1S 0 1S 1 5S 1 5S 60S 205V 47 5Hz 0 1S 0 1S 1 5S 1 5S 60S 205V 47 5Hz 0 1S 0 1S 5S 60S 205V 47 5Hz 0 1S 0 1S 1 5S 60S 196V 47 5Hz 0 1 2S 0 1 2S 1 6S 1...

Page 22: ...New Password X X X X ESC UP DOWN ENT YES ENT NO ESC Figure 5 30 Reset Password Figure 5 28 Total Energy Adjusting total generating power 2015 02 23 19 35 Total Energy ESC UP DOWN ENT YES ENT NO ESC T...

Page 23: ...multiple battery models Please refer to the latest compatible battery list on Solis company website WARNING Inverter must be installed with compatible battery models Any defect damage or collateral l...

Page 24: ...ry Values are examples Only Temp Compensation 072mV degC 1 Battery Capacity Define the capacity of the battery 2 Equalizing Voltage Define the voltage for Equalizing Absorption charge 3 Floating Volta...

Page 25: ...With CT SDM120CTM Optional Eastron 3ph meter Direct Insert SDM630M Optional Eastron 3ph meter With CT SDM630MCT Optional No meter is connected 5 6 6 3 2 Meter Placement Grid Meter is installed at the...

Page 26: ...ttery wakeup function before nishing the rst commissioning 5 6 6 5 Battery Wakeup 5 6 7 Export power Set Settings Figure 5 40 Export power Set Export power Set 2015 02 23 19 35 Back ow Power ON OFF Fa...

Page 27: ...PDATE SYSTEM ENT Figure 5 46 BaudRate RS485 Settings BaudRate RS485 2015 02 23 19 35 YES ENT NO ESC Baud Rate 9600 ESC UP DOWN ENT 5 6 10 BaudRate RS485 This function is to change the internal communi...

Page 28: ...n fixed or it is confirmed to be OK press ESC for 3s and wait for the inverter to restart Figure 5 47 Special Setting Settings Special Setting 2015 02 23 19 35 AFCI Set EPS Mode YES ENT NO ESC 5 6 11...

Page 29: ...meet the requirements proceed as follows to start up the inverter for the first time 1 Turn on PV DC switch 2 Turn on battery breaker or battery switch button on the battery 3 Select the grid standard...

Page 30: ...inverter may stop feeding energy into the grid The alarm descriptions and their corresponding alarm messages are listed in Table 8 1 56 57 Settings Advanced Information 2015 02 23 19 35 Warning Messag...

Page 31: ...G IMP NO GRID OV BUS GRID INTF01 02 INI FAULT Failure description High grid impedance No grid voltage Over DC bus voltage Grid interference Initialization system fault Solution 1 Check connections and...

Page 32: ...G V01 02 12Power FAULT 12V power supply fault 1 Restart inverter or contact installer Table 8 1 Fault message and description 8 Troubleshooting AFCI self detection model with AFCI module AFCI module s...

Page 33: ...frequency range Rated grid output current 15 0 A 45 55 Hz 18 5 A The grid voltage range Rated grid frequency 187 265 V 50 Hz Operation phase Rated grid voltage 1 N PE 230 V Dimensions W H D 333 505 24...

Page 34: ...87 265V 31 5 A 45 55 Hz Max input current 20ms Rated output power 5kW 4 6kW Max apparent output power Rated apparent output power 5kVA 5kVA 4 6kVA 4 6kVA Output AC Grid side Power Factor Max efficienc...

Page 35: ...5 A 45 55 Hz Max input current 20ms Li ion Lead acid 100A 5kW Features Quick connection plug AC connection Communication Warranty RS485 Optional Wi Fi GPRS 5 years standard extand to 20 years Display...

Page 36: ...1 CEI 0 21 C10 11 NRS 097 2 1 TOR EIFS 2018 2 IEC 62116 IEC 61727 IEC 60068 IEC 61683 EN 50530 MEA PEA Safty EMC standard IEC EN 62109 1 2 EN 61000 6 2 3 3000m Max operation altitude MC4 connector DC...

Page 37: ...er Make sure the polarities of battery is correct before connecting to the inverter Please follow the instructions below to choose the battery power cable NOTE Power cable uses water proofed AMPHENOL...

Page 38: ...1 rstly Then assemble back shell item 4 onto the connector body item 1 and tighten No gap When 16mm cable apply assembly barrelinto lug rstly as shown Then put the conductor into the lug Tie closely i...

Page 39: ...ed it can also come from Grid If Time of Use is Run the logic will follow the charging discharging settings and time settings as defined in Time of Use For those undefined period of time it will still...

Page 40: ...harging From Grid is allowed it can also come from Grid If Time of Use is Run the logic will follow the charging discharging settings and time settings as defined in Time of Use For those undefined pe...

Page 41: ...ed settings under STD Mode Settings NOTE The following sections have restricted access Only authorized personnel are allowed to modify the settings Please contact Solis service team for XXXX password...

Page 42: ...tor 3 1 Disable Description This mode will disable the reactive power response working modes 3 2 Volt Var Description Inverter will change the reactive output power based on grid voltage 80 81 Vv1 Vv2...

Page 43: ...DRM ON OFF is used to enabled or disable the functionality of the DRM port DRM3 and DRM7 are used to define the reactive power absorption for DRM3 and DRM7 Range 0 60 OVF_Start F_ULCO 50 1Hz 50 5Hz De...

Reviews: