3-2. Rear Panel Operations
:
WARNING
: REVERSE POLARITY
WILL DAMAGE UNIT
CHASSIS
GROUND
REMOTE
PORT
DC INPUT
NEG(-)
POS(+)
POS(+)
DC INPUT
WARNING
: REVERSE POLARITY
WILL DAMAGE UNIT
CHASSIS
GROUND
NEG(-)
3-2-1. Remote ON / OFF switch for S600R model only.
3-2-1-1. In order for the Remote ON / OFF switch to operate inverter,
ON / OFF switch on the Front Panel must be off.
3-2-1-2. Make sure the remote control contact is off.
3-2-1-3. Using 14 ~ 20 AWG wire, make remote ON / OFF connection
from the Rear Panel Terminal marked “REMOTE PORT” to a
remote control contact. If the remote control contact is in low
impedance ( short ) state, the inverter will be turned ON and if
the remote control contact is in high impedance ( open ) state,
the inverter will be turned OFF.
7
Summary of Contents for S600 Series
Page 1: ...S600 S600R Series Pure Sine Wave Inverter User s Manual ...
Page 6: ...2 3 Mechanical Drawings P U R E S IN E W A V E IN V E R T E R 4 ...
Page 20: ...7 1 CE LVD EN60950 Declaration of Conformity 18 ...
Page 21: ...7 2 FCC Class B Declaration of Conformity 19 ...
Page 22: ...7 3 e mark e13 020866 Declaration of Conformity 20 ...
Page 23: ...7 3 e mark e13 020866 Declaration of Conformity 21 ...