4. Troubleshooting guide
:
WARNING!
Do not open or disassemble the S600 Inverter.
Attempting to service the unit yourself may result in a
risk of electrical shock or fire.
Problems and Symptoms Possible Cause
Solutions
No output voltage, ”FAULT" LED lights RED.
a. Fault level light is
blinked fast.
Over input voltage.
( OVP )
Check input voltage.
Reduce input voltage.
b. Fault level light is
blinked slowly.
Low input voltage.
( UVP )
Recharge battery.
Check connections
and cable.
c. Fault level light is
blinked Intermittently.
Thermal shutdown.
( OTP )
Improve ventilation.
Make sure ventilation
openings in inverter
are not obstructed.
Reduce ambient
temperature.
d. Fault level light is ON. Short circuit or Wiring
error.
Overload.
( OLP )
Check AC wiring for
short circuit.
Reduce load.