3-4-3. Before proceeding further, carefully check that cable you have
connected does tie negative terminal of inverter to the negative
output power source.
CAUTION !
Reverse polarity connection will blow a fuse in inverter
and may permanently damage the inverter.
Damage caused by reverse polarity connection is not
covered by warranty.
3-4-4. Connect the cable from the negative terminal of the inverter to the
negative terminal of the power source. Make a secure connection.
3-4-5. Set the power switch to the “ON” position and the buzzer will send
out “Beep sounds” sounds at the moment the inverter will do
self-diagnosis and the LED’s indicators will also appear various
colors. Finally the buzzer will send out another “Beep” sound and
the Input Level LED indicators will turn to “Green” color and the
inverter starts working successfully.
3-4-6. Set the power switch to the OFF position, the inverter stops and all
the lights that are On, and then go Off.
3-4-7. Set power inverter switch to the ON position and turn the test load
on. The inverter should supply power to the load. If you plan to
accurately measure the true output r.m.s. voltage of inverter, a meter
such ad FLUKE 45 BECKMAN 4410 or TRIPLETT 4200 must be
used.
11
Summary of Contents for S600 Series
Page 1: ...S600 S600R Series Pure Sine Wave Inverter User s Manual ...
Page 6: ...2 3 Mechanical Drawings P U R E S IN E W A V E IN V E R T E R 4 ...
Page 20: ...7 1 CE LVD EN60950 Declaration of Conformity 18 ...
Page 21: ...7 2 FCC Class B Declaration of Conformity 19 ...
Page 22: ...7 3 e mark e13 020866 Declaration of Conformity 20 ...
Page 23: ...7 3 e mark e13 020866 Declaration of Conformity 21 ...