Other DAws + Sigma
Sigma remote Settings
1.
Open the Sigma Remote application and go to the
‘Settings’ page.
2. Set ‘Control Protocol’ to
Delta (MCU)
from the drop-down
box (see image). This will prompt a reboot of your Sigma.
DAw Settings
1.
It is advised that you configure the
δ
-Ctrl plugin to be
easily accessible from your plugin menu for quicker mix
setup.
2. Open the automation settings for your DAW, and
configure them to best work with Sigma (default to latch,
plugin parameters are all auto-enabled etc).
Session Setup
The final step is to setup the
δ
-Ctrl plugin(s).
δ
-Ctrl Single Plugin Setup (Not available as AU)
1.
Insert a
δ
-Ctrl single plugin on any track.
2. Set the Console Type to
SIGMA
, Console Object to
CHAN
, and Console Object Number to
1
. Ctrl-click on the Console
Object Number (1) to use auto-increment feature – the number will now be greyed out. This feature can be disabled
by a second Ctrl-click on the Console Object Number.
3. Manually add 15 extra
δ
-Ctrl single plugins to any channel inserts. The Console Object Number will be configured
automatically if the auto-increment feature is enabled. Sigma channel names will be pulled from the Sigma Remote
app to the corresponding
δ
-Ctrl plugin.
It is recommended that the
δ
-Ctrl plugins are added to channels with the corresponding output to Sigma (for example,
the
δ
-Ctrl plugin that controls channel 4 of Sigma added to the insert of the Pro Tools audio track routed to output 4
on your audio interface). This is useful for writing automation over the waveform of the audio track.
4. Make sure that your track automation status is set to either Read, Touch, or Latch. As the
δ
-Ctrl plugin uses standard
DAW automation tracks, you can now automate Sigma using the DAW automation system.
δ
-Ctrl 16 plugin Setup
1.
Insert the
δ
-Ctrl 16 plugin on any track.
2. Make sure that your track automation status is set to either Read, Touch, or Latch. As the
δ
-Ctrl plugin uses standard
DAW automation tracks, you can now automate Sigma using the DAW automation system.
The default state of the plugin is with all switches off and the absolute value of the fader at ∞, these are the initial
breakpoints stored in the track automation playlists in the DAW. When the
δ
elta-Ctrl mix system is enabled channels
assigned to plugins will be reset to the values stored in the playlists, which if no mix data has been saved, will be
the default settings. Double clicking the plugin Fader will reset the Sigma Volume back to 0dB which is the Sigma
default value. Alternatively, the Remote app 0dB button can be used.