- 5-
3.1-4 Controller
The unit is equipped with an external electronic controller that handles all functions necessary for
heat pump operations. Defrosting, stop at max/min temperature, connection of the compressor
heater as well as enabling the aux electrical heater, monitoring of motor protection and pressure
switches are all controlled.
The number of starts and the operating time can also be read.
The controller is set during installation and can be used during a service.
Under normal operating conditions the home owner does not need to have access to the controller.
The unit has an integrated electronic outlet water temperature sensor that limits the outlet
temperature up to 60°C.
3.2 Installation design
The unit can be installed in several different ways.
The safety equipment must be installed in accordance with current regulations for all installation
options.
When connecting with the unit, the total water volume in the heat pump pipe system and buffer
tank must be at least 10 liters per KW of output.
A) Space Heating/C DHW