- 22-
4.7 Parameter check(Only checkable parameter list)
Press
key for 6 seconds
,
it will show Hxx to check the above parameter
Touch
or
key to check different parameter.
No Name
Range / meaning
Remark
H00 Inlet water temperature
-40~97° C
H01 Outlet water temperature
-40~97° C
H02 DHW water temperature
-40~97° C
H03 Ambient temp
-40~97° C
H04 Indoor air temp
-40~97° C
reserved
H05 Compressor discharge temp
5~128° C
H06 Suction temp
-40~97° C
H07 Coil temperature
-40~97° C
H08 Liquid refrigerant temperature
-40~97° C
H09 EVI inlet temp
-40~97° C
reserved
H10 EVI outlet temp
-40~97° C
reserved
H11 Water source inlet temp
-40~97° C
reserved
H12 Water source outlet temp
-40~97° C
reserved
H13 IPM temperature
-40~97° C
H14 Solar pipe temperature
40~97° C
reserved
H15 Running frequency
H16 Compressor current
H17 EEV open steps/2
H18 EVI EEV open steps/2
reserved
H19 Water flow value
L/min
H20 Low pressure value
MPa
reserved
H21 High pressure value
MPa
reserved
H22 EC motor 1 speed
RPM
reserved
H23 EC motor 2 speed
RPM
reserved
H24 reserved
H25 Compressor present stop code
H26 Compressor last time stop code
H27 Compressor before last time stop code
H28 Compressor before three times stop code
H29 Cumulative running time of compressor (high 3 bits)
H30 Cumulative running time of compressor(low 3 bits)
H31 Defrost times
Summary of Contents for GAG-08DC
Page 1: ... 1 DC INVERTER AIR TO WATER HEAT PUMP User Manual Model GAG 08DC 12DC 16DC ...
Page 6: ... 6 B Space Heating Cooling Mode Only C 2x8 12 16 Installation Space Heating Cooling DHW ...
Page 7: ... 7 D 3x8 12 16 Installation Space Heating Cooling DHW Solar Application 1 ...
Page 10: ... 10 Wiring Diagram GAG 16DC ...
Page 27: ... 27 5 2 System Drawing 5 3 Dimensions mm GAG 08DC ...
Page 28: ... 28 GAG 12DC GAG 16DC ...