- 20-
4.6 System Adjustable Parameter Table
Press
key for 6 seconds
,
Press
key for 6 seconds again,
Press
key, enter the
the screen will show Hxx.
then enter the password window.
parameter check window.
Press
or
key to check different parameter.
Code Name
Range
Default
F00
Parameter’s value return to default
0~255 : 10(return)
0
F01
Auto restart
0:off, 1:on
1
F02
Functional parameter
0: only heating 1:heating
2: only cooling 3: DHW+(C+H)
3
F03
AC temp difference
1~30°C
,
minus difference
2°C
F04
DHW temp difference
1~30°C
,
minus difference
3°C
F05
AC auxiliary electric heater E2 validation
0: Invalid; 1:valid
0
F06
Ambient temperature to activate E2
-20~30°C
7°C
F07
The time of delayed to active E2
1~99 minutes
20
F08
DHW auxiliary electric heater E1 validation
0: Invalid; 1:valid
0
F09
Ambient temperature to activate E1
-20~30°C
7°C
F10
The time of delayed to active E1
1~99 minutes
20
F11
Water pump working mode
0(no stop),1(stop when reach temp)
2(running 1 minute every (15=F12)minutes)
F12
Water pump mode 2 interval time(F11=2)
1~99 minutes
15
F13
AC AU curve max temp value
30~50°C
45°C
F14
AC AU curve offset value
-10~10°C
0°C
F15
Auto remove error
0: no remove; 1~255minutes
30
F16
Sterilization temperature
40~80°C
65°C
F17
Sterilization interval time
0:sterilization invalid; 1~99 days
7
F18
Sterilization duration
1~99minutes
10
F21
Night mode validation (night mode: DHW
increase 3C, AC temp reduce 2C)
0:invalid; 1:valid
0
F22
Night mode starting point
0-23(time)
21
F23
Night mode ending point
0-23(time)
6
F24
Compressor and Motor speed’s output
ratio for night mode
0-100
80
F30
Defrost interval time
10~200 minutes
50
F31
Defrost time(defrost action lasting max time,will
stop defrost if longer than this value)
5~20 minutes
8
F32
Coil temp to active defrost
-30~15°C
-5°C
F33
Coil copper pipe temp to stop defrost
10~35°C
25
°C
F34
Ambient temperature to active defrost
0~55°C
15
°C
F35
Difference between ambient and coil temperature
to active defrost(Ambient temp lower than -7°C)
0~25°C
8
°C
Summary of Contents for GAG-08DC
Page 1: ... 1 DC INVERTER AIR TO WATER HEAT PUMP User Manual Model GAG 08DC 12DC 16DC ...
Page 6: ... 6 B Space Heating Cooling Mode Only C 2x8 12 16 Installation Space Heating Cooling DHW ...
Page 7: ... 7 D 3x8 12 16 Installation Space Heating Cooling DHW Solar Application 1 ...
Page 10: ... 10 Wiring Diagram GAG 16DC ...
Page 27: ... 27 5 2 System Drawing 5 3 Dimensions mm GAG 08DC ...
Page 28: ... 28 GAG 12DC GAG 16DC ...