9. FICHE TECHNIQUE ECOCONCEPTION

Ecodesign

Commission regulation (EU) N°1253/2014 of July 2014

Information requirements (Annex V)

ORKA HR

a

Trade mark

S&P

b

Identifi er

5153833200

c

SEC average climate (kWh/(m2.an))

-26,2

SEC class

B

SEC cold climate (kWh/(m2.an))

-62,8

SEC warm climate (kWh/(m2.an))

-2,6

d

Typology

RVU bidirectional

e

Type of drive

3 speeds

f

Type of HRC

Recuperative

g

Thermal effi ciency (%)

84

h

Maximum fl ow rate (m3/h)

215

i

Electrical power input at maximum fl ow rate (W)

127,0

j

Sound power level (LWA)

50

k

Reference fl ow rate (m3/s)

0,042

l

Reference pressure difference (Pa)

65,0

m

SPI (W/m3/h)

0,551

n

Control factor

1

Control typology

Manual

o

Maximum internal leakage for BVU (%)

4

Maximum external leakage for BVU and UVU (%)

4

p

Mixing rate for BVU without duct connection (%)

Not apply

q

Position of visual fi lter warning

Remote control

description of visual fi lter warning

Pilot light

r

Instructions to install supply grilles

Not apply

Instructions to install exhaust grilles

Not apply

s

Internet address

www.solerpalau.com

Sensibilidad del fl ujo de aire a variaciones de presión 

No aplica

t

Airfl ow sensitivity to pressure variation

Not apply

u

Indoor/outdoor air tighness (m3/h)

Not apply

v

Annual electricity consumption - Average climat (kWh/a)

736

Annual electricity consumption - Warm climat (kWh/a)

691

Annual electricity consumption - Cold climat (kWh/a)

1273

w

Annual heating saved - Average climat (kWh/a)

43,9

Annual heating saved - Warm climat (kWh/a)

19,9

Annual heating saved - Cold climat (kWh/a)

85,9

Summary of Contents for ORKA HR D150

Page 1: ...ORKA HR EN ...

Page 2: ......

Page 3: ... mental capabilities or lack of experience and knowledge if they have been given supervision or instruc tion concerning use of the appliance in a safe way and understand the ha zards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision ...

Page 4: ...ections 5 Control of ORKA 6 Commissioning the ORKA 7 Maintenance 8 Putting out of service and recycling The following items are included 1 1 x ORKA HR D150 2 1 x remote control 3 1 x condensate drain tube support 4 3 x positioning accessories 5 3 x reductions Ø 125 160 6 1 x plug 125mm 7 1 x instruction manual ...

Page 5: ...A HR D150 has been designed to be incorporated into a ventilation system Following insta llation there should be no risk to safety health and the environment according to EC directives This also applies to other products used in the installation The following general guidelines are important Follow the safety instructions to prevent injuries and damage to the motorised fans The technical character...

Page 6: ...f bathroom and kitchen Supply to living room and bedrooms Covers to filters access New fresh air inlet This spigot is to connect the supply duct of fresh air from outside Install the fresh air intake wall or roof a sufficient distance from any area of high pollution trees exhaust fumes road etc To avoid short circuiting the terminal should also be positioned a minimum of 1 5m from the discharge air ...

Page 7: ... of the ORKA allows the introduction of cooler fresh air during the evenings and in the night avoiding the heat exchanger and thus without it being tempered by the outgoing warm air which has accumulated in the house during the day Alarm filter change the unit has a timer 12 months TIMER that alerts the user when to change the filters 2 3 DIMENSIONAL CHARACTERISTICS 2 3a Central Weight 20 kg 2 3b Re...

Page 8: ...that regularly have negative temperatures 2ºC a pre heating battery must be installed Operating temperature 2ºC 45ºC Ducts must be thermally insulated and correctly installed ORKA has been designed to be installed indoors Uninsulated duct Insulated duct Insulated duct Spigot arrangement Ø 150 mm Spigots that are not used must be plugged with the supplied accessory ...

Page 9: ...ories The condensate outlet that is not used must be plugged with the supplied plug The condensate tube must maintain the slope throughout its length Fix the duct if it is necessary Installation should have a siphon filled with water as indicated For correct maintenance a sufficiently large equipment access hatch must be installed Recommended Dimensions 1000 x 750 mm ...

Page 10: ...ensate outlet that is not used must be plug ged with the supplied plug The condensate tube must maintain the slope throughout its length Fix the duct if it is neces sary Installation should have a siphon filled with wa ter as indicated For correct maintenance access must be allowed to the equipment to each exposed side Access is from the top ...

Page 11: ... sections and must be correctly stretched It is recommended not to put the RDR flow regulator on a branch both in extraction kitchen and in supply living room to take advantage of the peak flow activated by the remote control Kitchen Toilets Living room bedrooms BDO or TPM 80 CPR or CT 125 ...

Page 12: ... sections and must be correctly stretched It is recommended not to put the RDR flow regulator on a branch both in extraction kitchen and in supply living room to take advantage of the peak flow activated by the remote control Kitchen Toilets Living room bedrooms BDO or TPM 80 CPR or CT 125 ...

Page 13: ...hort sections and must be correctly stretched It is recommended not to put the RDR flow regulator on a branch both in extraction kitchen and in supply living room to take advantage of the peak flow activated by the remote control Kitchen Toilets Living room bedrooms CPR or CT 125 ...

Page 14: ...ICS AND ELECTRICAL CONNECTIONS Power Single phase 230V 50Hz Max current 0 7 A Electrical protection 2 A curve C Max Power 145 W Maximum ambient temperature 50ºC Maximum flow temperature 45ºC Configuration A Configuration B ...

Page 15: ... seconds during the first 4 days Subsequently the flashing will be every 30 seconds for the next 9 days When the filters have been changed the alarm must be reactivated by pressing the button for 5 seconds To check the remaining time until the end of the timing press the button for 3 seconds and the pilot light will illumi nate a number of times to the number of months remaining to reach 12 months To...

Page 16: ... use the following process 1 Verify that all system components are correctly installed and connected Fresh air intake duct insulated and connected correctly Do not use a fresh air intake equipped with insect screen Fresh air and exhaust ducts insulated and connected correctly Fresh air and exhaust vents connected Flow regulators mounted in the right direction if installed Air outlet using insulate...

Page 17: ...s remove dust from inside of the heat recovery unit with a vacuum cleaner Every 6 months clean the extraction spigots of kitchen and bathroom with warm water and soap 8 PUTTING OUT OF SERVICE AND RECYCLING EEC legislation and our consideration of future generations mean that we should always recycle materials where possible please do not forget to deposit all packaging in the appropiate recycling ...

Page 18: ... Maximum internal leakage for BVU 4 Maximum external leakage for BVU and UVU 4 p Mixing rate for BVU without duct connection Not apply q Position of visual filter warning Remote control description of visual filter warning Pilot light r Instructions to install supply grilles Not apply Instructions to install exhaust grilles Not apply s Internet address www solerpalau com Sensibilidad del flujo de air...

Page 19: ......

Page 20: ...S P SISTEMAS DE VENTILACIÓN S L U C Llevant 4 Polígono Industrial Llevant 08150 Parets del Vallès Barcelona España Tel 34 93 571 93 00 Fax 34 93 571 93 01 www solerpalau com Ref 9023090800 ...

Reviews: