5
1. GENERAL INFORMATION
1.1. INTRODUCTION
This manual is intended for the use of the central balanced-fl ow high effi ciency ORKA HR D150 and its peripherals
(ductwork, vents, controllers).
It is designed to provide clear and safe guidance for the design, installation and use of the product.
The products are constantly evolving and so, Soler & Palau reserves the right to modify this manual without prior
notice.
1.2. WARRANTY AND LIABILITY
Warranty
The ORKA HR D150 heat recovery system has two years warranty from the date of purchase. This warranty includes
free delivery of necessary spare parts.
The warranty does not cover:
Installation and removal costs.
Defects that, in the opinion of Soler & Palau, are due to improper installation, handling, neglect or accidental damage.
Those defects that arise as a result from operations or repair performed by a third party without permission from
Soler & Palau.
To return a defective part, the user should contact their installer.
Liability
ORKA HR D150 is designed for ventilation systems in individual dwellings. Soler & Palau is not responsible for da-
mage caused by:
• Improper use.
• Normal wear of components.
• Failure to follow the instructions in this manual concerning safety, use and installation.
• The use of parts not supplied by Soler & Palau.
1.3. SAFETY
General health and safety standards
The heat exchanger ORKA HR D150 has been designed to be incorporated into a ventilation system. Following insta-
llation, there should be no risk to safety, health and the environment according to EC directives. This also applies to
other products used in the installation. The following general guidelines are important:
• Follow the safety instructions to prevent injuries and damage to the motorised fans.
• The technical characteristics described in this manual may not be changed.
• The motorised fans must not be modifi ed.
• The motorised fans must be supplied with a single phase AC supply of 230 V / 50 Hz.
• So that the installation complies with EC directives, the ORKA HR D150 must be connected to the electricity grid
according to current national standards.
• The device must be installed so that under normal operating conditions, there is no risk of contact with moving
parts and power.
• The ORKA HR D150 meets legal requirements for electrical equipment.
• Before working on the machine, always turn the power off.
• Use appropriate tools.
• Use the machine only for the purpose for which it is intended.
2. GENERAL INFORMATION
2.1. INTRODUCTION
ORKA ensures optimal ventilation of the house with maximum energy recovery. Stale air is extracted from the “wet”
rooms (bathrooms, toilets, laundry rooms, etc.) and fresh air is supplied into the main “habitable” rooms (living
room, bedrooms,studys,...).
Both airfl ows are fi ltered before forwarding to the heat recovery unit, where warmth from the stale, outgoing air is
transferred to the cooler incoming airfl ow. The unit performance can reach:
• HR: 92%
• ST:70%