background image

                                                                                                                                              

  

              

                         

 

 

12 

AC Connector 

 

 

Plug-in connector 

 

Power consumption 

 

Own consumption in operation 

P

own(AC) 

  [W] 

50 

Power consumption at night 

P

nig(AC) 

   [W] 

Power consumption at standby 

P

std(AC) 

   [W] 

Efficiency 

Max. Efficiency (at 360VDC) 

 

97.6% 

Euro efficiency (at 360VDC) 

 

 

97.0% 

MPPT efficiency 

 

99.9% 

Safety and protection 

Internal overvoltage protection 

 

Yes 

DC Insulation monitoring 

 

 

Yes 

Earth fault protection    

 

Yes 

Grid monitoring  

 

 

According to VDE 0126-1-1, RD1663, ENEL2010,C10/11, 

G83/1, AS4777 

Earth fault current monitoring 

 

According to VDE 0126-1-1, RD1663, ,ENEL2010,C10/11, 

G83/1, AS4777 

DC current monitoring 

 

 

According to VDE 0126-1-1, RD1663, ENEL2010,C10/11, 

G83/1, AS4777 

Islanding protection 

 

 

According to VDE 0126-1-1, RD1663, G83/1, AS4777 

Normative reference 

CE- compliant according to  

 

EN 62109, EN 61000-6-1, EN 61000-6-3, EN 61000-6-2, EN 

61000-6-4  

 

EN61000-3-2, EN61000-3-3, EN61000-3-12, EN61000-3-11 

Dimensions and weight 

Dimensions (WxHxD)  

[mm] 

367x526x163 

Weight  

[kg] 

21 

Environmental limits 

IP protection type  

 

 

IP 65 according to IEC 60529 

Operating temperature range 

 

 

-20°C to +60°C 

Relative humidity 

 

 

0% to 98%, no condensation 

Maximum altitude (above sea level) 

[m] 

2000 

Noise level 

[dBA] 

< 40 

General data 

Isolation type 

 

 

Transformerless 

Cooling concept 

 

 

Convection 

Housing 

 

 

metal housing for inside and outside installation 

Mounting information 

 

 

Wall bracket 

LED display 

 

 

LCD display 

 

 

Backlight, 16 x 2 Character LCD 

Data logger 

 

 

RS485, Optional (Wi-Fi, GPRS, Ethernet) 

Data communication interfaces 

 

 

Computer Communication 

 

 

RS232 as Option 

Standard warranty  

 

 

5 years (optional 10 years) 

 

 

 

Summary of Contents for OXYGEN 3400

Page 1: ...User Manual V1 0 User Manual Installation Operation OXYGEN 3400 OXYGEN 4500 OXYGEN 5000 SOLEOS solar GmbH ...

Page 2: ......

Page 3: ...15 4 1 Assembly Parts 15 4 2 Product Appearance 16 4 3 Product Identification 17 4 4 Further Information 17 5 Installation 18 5 1 Safety 18 5 2 Mounting Instructions 18 5 3 Safety Clearance 19 5 4 Mounting Procedure 20 5 5 Safety Lock with the wall mounting bracket 22 6 Electrical Connection 23 6 1 Safety 23 6 2 Overview of Connection Area 24 6 3 AC Side Connection 25 6 4 DC Side Connection 27 6 5...

Page 4: ...2 7 3 Set Language 36 7 4 Choosing Safety Regulation After Starting Up 37 7 5 State Information 39 8 Recycling and Disposal 40 9 Troubleshooting 41 10 Abbreviation 42 11 Contact 43 ...

Page 5: ...user manual all time available in case of emergency 1 2 Symbols Used DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided can result in death or serious injury or moderate injury CAUTION CAUTION indicates a hazardous condition which if not avoided can result in minor or moderat...

Page 6: ...are only for qualified personnel who are intended to install or uninstall the Soleos Grid Tie Solar Inverter WARNING Do not use this product unless it has been successfully installed by qualified personnel in accordance with the instructions in Chapter 5 Installation NOTICE Hereby qualified personnel means he she has the valid license from the local authority in Installing electrical equipment and...

Page 7: ...le there is severe weather conditions including storm lighting etc WARNING The installation service recycling and disposal of the inverters must be performed by qualified personnel only in compliance with national and local standards and regulations Please contact your dealer to get the information of authorized repair facility for any maintenance or repairmen Any unauthorized actions including mo...

Page 8: ...e you remove the front lid NOTICE danger This device directly connected with electricity generators and public grid CAUTION The PV inverter will become hot during operation please don t touch the heat sink or peripheral surface during or shortly after operation Risk of damage due to improper modifications Never modify or manipulate the inverter or other components of the system NOTICE Public utilit...

Page 9: ...ark of conformity The inverter complies with the requirement of the German Grid Regulations Certified Safety The inverter complies with the requirements of the Equipment and Product Safety Act in Europe Standards Association of Australian The inverter complies with the requirement of the AS4777 CE Mark Equipment with the CE mark fulfils the basic requirements of the Guideline Governing Low Voltage...

Page 10: ...8 3 Product Information 3 1 Overview Industrial Layout Excellent Heat Elimination ...

Page 11: ...enables more PV panels connected Wide MPP voltage range ensure high yield under various weather conditions High MPP tracking accuracy ensure the minimum power loses during converting Complete set of protection methods Also following protection methods are integrated in Soleos inverter Internal overvoltage DC insulation monitoring Ground fault protection Grid monitoring Ground fault current monitor...

Page 12: ...er factor 0 99 30 of Full Load Harmonic distortion THD at nominal output 2 AC Connector Plug in connector Power consumption Own consumption in operation Pown AC W 45 Power consumption at night Pnig AC W 0 Power consumption at standby Pstd AC W 6 Efficiency Max Efficiency at 360VDC 97 4 Euro efficiency at 360VDC 96 6 MPPT efficiency 99 9 Safety and protection Internal overvoltage protection Yes DC ...

Page 13: ...on interfaces Computer Communication RS232 as Option Standard warranty 5 years optional 10 years OXYGEN 4500 Type OXYGEN 4500 Input DC Max PV generator power Ppv W 4500 Max DC voltage Vmax DC V 590 MPPT DC voltage range Vmppt V 120 500 Turn off DC Voltage Vmin DC V 120 Max DC current Imax DC A 36 Nominal DC current IN DC A 33 Number of DC connection 2 DC connection MC4 Number of MPP trackers 2 Tur...

Page 14: ...ccording to VDE 0126 1 1 RD1663 G83 1 AS4777 Normative reference CE compliant according to EN 62109 EN 61000 6 1 EN 61000 6 3 EN 61000 6 2 EN 61000 6 4 EN61000 3 2 EN61000 3 3 EN61000 3 12 EN61000 3 11 Dimensions and weight Dimensions WxHxD mm 367x526x163 Weight kg 21 Environmental limits IP protection type IP 65 according to IEC 60529 Operating temperature range 20 C to 60 C Relative humidity 0 t...

Page 15: ...or 0 99 30 of Full Load Harmonic distortion THD at nominal output 2 AC Connector Plug in connector Power consumption Own consumption in operation Pown AC W 50 Power consumption at night Pnig AC W 0 Power consumption at standby Pstd AC W 6 Efficiency Max Efficiency at 360VDC 97 6 Euro efficiency at 360VDC 97 0 MPPT efficiency 99 9 Safety and protection Internal overvoltage protection Yes DC Insulat...

Page 16: ... to 98 no condensation Maximum altitude above sea level m 2000 Noise level dBA 40 General data Isolation type Transformerless Cooling concept Convection Housing metal housing for inside and outside installation Mounting information Wall bracket LED display 3 LCD display Backlight 16 x 2 Character LCD Data logger RS485 Optional Wi Fi GPRS Ethernet Data communication interfaces Computer Communicatio...

Page 17: ...mpleteness for any visible external damage on the inverter or any accessories Contact your dealer if anything is damaged or missing A B C D E F G H Object Quantity Description A 1 Soleos inverter B 2 pairs DC connector C 1 AC connector D 1 Mounting bracket E 4 Screw ST6 50 F 4 Expansion tube G 1 Installation and operating instructions H 1 DC Switch Optional ...

Page 18: ...Front Object Description A Removable front shield B LED light Green RUN C LED light Red FAULT D LED light Yellow COM E Function key for displays and choice of language F Monitoring LCD with backlighting Bottom A B C A B C D E F ...

Page 19: ...SN type of the inverter as well as inverter specifications are specified on the side name plate The name plate is on the middle part of the right side of the inverter housing And the following figure is the side name plate example as on OXYGEN 3400 4 4 Further Information If you have any further questions concerning the type of accessories or installation please check our website www soleos solar ...

Page 20: ...connected with HIGH VOLTAGE power generation device the installation must be performed by qualified personnel only in compliance with national and local standards and regulations NOTICE NOTICE due to the inappropriate or the harmonized installation environment may jeopardize the life span of the inverter Installation directly expose under intensive sunshine is not recommended The installation site...

Page 21: ...e the device is properly fixed to the wall It is not recommended that the inverter is exposed to the strong sunshine because the excess heating might lead to power reduction The ambient temperature of installation site should be between 20 C and 60 C between 4 F and 140 F Make sure the ventilation of the installation spot not sufficient ventilation may reduce the performance of the electronic comp...

Page 22: ...ing to the wall mounting bracket in the carton box 300 253 Depth 50mm 2 According to the marks drill 4 holes in the wall Then place four expansion tubes in the holes using a rubber hammer Next make 4 screws through the mounting holes in the bracket then tighten the screws into the expansion tubes so far the wall mounting bracket is fixed already ...

Page 23: ... 3 Check the 4 holes in the backside of the inverter Then lift the inverter carefully align the 4 holes in the inverter and the 4 hooks on the bracket and finally attach the inverter to the hooks slightly ...

Page 24: ...Safety lock with the wall mounting bracket After the inverter is hang up on the bracket lock up the device and the bracket together at the Lower Right Corner of the inverter as the picture showed below Padlock ...

Page 25: ...ssible repair please keep the key of the padlock in a safe place DANGER DANGER to life due to potential fire or electricity shock With the inverter powered comply with all prevailing national regulations on accidents prevention This inverter will be directly connected with HIGH VOLTAGE power generation device the installation must be performed by qualified personnel only in compliance with nationa...

Page 26: ...tion A Plug connectors for DC input B RS232 RS485 interface C Terminal for grid connection AC output NOTICE Electrical connections shall be carried out in accordance with the applicable regulations such as conductor sections fuses PE connection A B C ...

Page 27: ... compare it with the pre set value if the leakage current exceeds the permitted range the RCD will disconnect the inverter from the AC load 2 Assembly Instructions a Strip the cable with the length 0 276 inches 9 32 7mm and please be careful NOT to nick conductors b Screw off and separate each component of AC connector as follows DANGER DANGER to life due to potential fire or electricity shock NEV...

Page 28: ...ug Then insert the stripped N L and PE cable accordingly to the corresponding position and fully tighten the screws e Aim the terminals on the straight plug to the holes of the grommet and then compress them together f Finally connect the straight plug to the AC terminal on inverter Pay attention to the polarity of the terminals to avoid wrong connecting ...

Page 29: ...eparation and assembly instructions described here are disregarded then neither safety nor compliance with the technical data can be guaranteed For protection against electric shock PV connectors must be isolated from the power supply while being assembled or disassembled The end product must provide protection from electric shock The use of PVC cables is not recommended NOTICE DC Switch Optional ...

Page 30: ...er with sealing caps Plugged parts are watertight IP67 They can not be used permanently under water Do not lay the MC PV connectors on the roof surface See the MC catalogue 2 Solar line for technical data and assembled parts PV Female cable coupler PV Male cable coupler Optional PV KBT4 PV KST4 PV SSH4 Touch protection mated unmated IP67 IP2X Rated current 17A 1 5mm2 14AWG 22A 2 5mm2 12AWG 30A 4mm...

Page 31: ...0 ill 3 Open end spanner PV MS 1 set 2 pieces Order No 32 6024 ill 4 PV WZ AD GWD socket wrench insert to tighten Order No 32 6006 ill 5 PV SSE AD4 socket wrench insert to secure PV SSE AD4 Order No 32 6026 ill 6 Open end spanner A F 15 mm ill 7 Torque screwdriver A F 12 mm ill 8 Test plug PV PST Order No 32 6028 ...

Page 32: ...ction may exceed the permitted limits Check dimension b according to the following table ill 10 Strip cable insulation L 6 7 5 mm Take care not to cut individual strands Recommended tool Stripping pliers PV AZM Order No 32 6027 Crimping ill 11 Notes to the operation ofthe crimping pliers see MA251 def www multicontact com ill 12 Push the crimped contact into the socket resp plug insulator until it...

Page 33: ...nd PV SSE AD4 In any case The tightening torque must be adapted to the solar cables used in each specific case Typical values lie in a range between 2 5 Nm to 3 Nm Plugging and unplugging the cable coupler without safety lock clip PV SSH4 Plugging ill 15 Plug the coupling together until they engage Check correct engagement by pulling on the coupling Unplugging ill 16 Compress the two snap in sprin...

Page 34: ...hese 2 plugs are used for multipoint communications that is up to 50 Soleos inverters can be connected one by one through these 2 plugs and the cables the upper computer can communicate with these inverters via a single signal cable at the same time and maximum length of the cable is 1000m Through these plugs the user can get the data from these inverters and can also configure parameters of them ...

Page 35: ... user to check and set the data In addition the user can press the function key to illuminate the LCD screen NOTICE Soleos inverter is not an aligned measuring instrument for current voltage or power consumption A slight deviation of a few percent points is intrinsic to the system the results from the inverter cannot be used for grid balance calculations An aligned meter will be required to make c...

Page 36: ...ower shortage 7 2 LCD Display The display content consists of 2 lines The bottom line Line 2 always displays the output power Pac xxxx W The top line Line 1 shows current state information by default and by pressing function key it will display different operating information as the following flow chart and table ...

Page 37: ...c xxxx W Iac Pac xxxx W E total Pac xxxx W Vpv Pac xxxx W Ipv Pac xxxx W E today Pac xxxx W Vac Pac xxxx W Model Pac xxxx W Ver Pac xxxx W Set language Pac xxxx W Frequency Pac xxxx W S N WiFi Pac xxxx W IP Address Pac xxxx W ...

Page 38: ...irmware version Set Language Several languages are provided for users reference to 7 3 for further information Vac The grid voltage S N WiFi Displays the serial number of the WiFi card such as no WiFi card shows 00000000 IP Address Displays the IP address of the WiFi such as don t connect WiFi card shows 0 0 0 0 7 3 Set Language The Soleos inverter provides several languages for users to use At th...

Page 39: ...0kW inverters Only perform this operation when the accumulative generated electricity is less than 1KWh 2 Operation steps are as following a Power on the inverter with only DC side connected while disconnecting cables of AC side b Press the Function button until the LCD displays inverter s model and hold the button for 5 seconds or more when the LCD displays the current Safety Standard Change the ...

Page 40: ...38 c When the LCD displays your desired Safety Standard hold the Function button for 5 seconds or more until it shows Safety Standard OK d The Safety Standard setup is now completed ...

Page 41: ...ty Loss No Utility Island PV Over Voltage Input voltage too high Over Temperature Temperature abnormal Isolation Fault Isolation failure Relay Check Fail Output relay failure DC INJ High Output DC injection too high EEPROM R W Fail EEPROM problem SCI Failure Serial communication interface failure AC HCT Failure Output AC sensor abnormal GFCI Failure GFCI testing device abnormal Flash F W Updating ...

Page 42: ... the end of its life must be collected separately and returned to an approved recycling facility Any device that you no longer required must be returned to your dealer or you must find an approved collection and recycling facility in your area Ignoring this EU Directive may have severe affects on the environment and your health WARNING This device SHALL NOT be disposed of in residential waste ...

Page 43: ...is not connected 2 Check grid connection cables 3 Check grid usability 4 If grid is ok and the problem persists maybe the fuse in the inverter is open please call service Over Temperature 1 The internal temperature is higher than specified normal value 2 Find a way to reduce the ambient temperature 3 Or move the inverter to a cooler environment PV over Voltage 1 Check the open PV voltage see if it...

Page 44: ...Maximum Power Point Impp Amperage at Maximum Power Point AC Alternating Current Form of electricity supplied by Utility Company DC Direct Current Form of electricity generated by PV modules VDE 0126 1 1 German standards for establishing suitability for Grid Connection of the Inverter DC Switch Switch in the DC Circuit Disconnects DC source from Inverter May be integrated or external to Inverter ...

Page 45: ...should confirm the follow things before contact us Device model Data collector serial number The number of connected inverter SOLEOS solar GmbH Add Lise Meitner Strasse 8 D 53332 Bornheim Germany Tel 49 2227 92 91 0 Fax 49 2227 92 91 22 Mail info soleos solar de Website www soleos solar com ...

Reviews: