Bench Test
35
1.
Start Hyperterminal on one of the workstations. (For Windows, go to Start|Acces-
sories|Hyperterminal.)
2.
In the Connection Description
Connection Description
Connection Description
Connection Description box, select a name and icon.
3.
In the Connect To
Connect To
Connect To
Connect To box, at “Connect using”, select COM 1.
4.
In the COM 1 Properties
COM 1 Properties
COM 1 Properties
COM 1 Properties box, select the following port settings:
• Bits per second: 115200
• Data bits: 8
• Parity: None
• Stop: 1
• Flow control: None
5.
From the Hyperterminal top menu, select File|Properties|Settings tab, and do the
following:
• From the Emulation menu, select “VT-100”.
• Type the ASCII setup button, and clear the wrap lines
wrap lines
wrap lines
wrap lines box.
6.
Start Hyperterminal again on the same workstation to open a new screen (if you
have connected the SkyWay to two COM ports), or start Hyperterminal on a sec-
ond workstation linked to the second SkyWay. Do the following:
• In the Connection Description
Connection Description
Connection Description
Connection Description box, select a new name and icon.
• In the Connect To
Connect To
Connect To
Connect To box, at “Connect Using,” select COM 2 if you are using one
computer and two com ports. If you are using a second workstation, select
COM 1.