4. Recommendations
4.1 The cold water piping should withstand pressure of 1000 kPa. The hot water piping should withstand
temperature of 95
o
C at pressure 1000 kPa.
4.2. The cold and hot water piping should be well insulated to eliminate heat losses and prevent as possible
freezing. The insulation material should withstand weather conditions like rains, snow and solar irradiation.
4.3. The system should be protected always with antifreeze liquid as supplied by the company to prevent
from frost.
4.4. On the hot water supply piping, install a reliable thermostatic mixing valve set at 55
o
C to prevent higher
temperature hot water to reach the consumption points.
4.5. The system may only be installed in locations with lower values of s
K
(snow load) 0.64m and v
m
(average
wind velocity) 97.2km/h
4.6. The required solar irradiation for which overheating will happen is shown on the table below. The system
should not be used in climate zones with higher irradiation values than these.
SWH 200-2-S200
H (MJm-2)
Tsn (°C)
15.20
31.72
25.01
32.13
19.42
28.69
24.16
30.98
26.42
31.48
26.88
31.62
27.42
32.88
27.94
35.07
27.40
33.82
26.59
35.01
27.21
35.75
Summary of Contents for EUROSTAR ECO 125-1-S150
Page 10: ...9 4 7 Thermal Performance of the System Model 125 1 S150 Model 125 1 S200...
Page 11: ...10 Model 150 1 S200 Model 150 1 S230...
Page 12: ...11 Model 150 2 S150 Model 200 1 S200...
Page 13: ...12 Model 200 1 S230 Model 200 1 S260...
Page 14: ...13 Model 200 2 S200 Model 300 2 S200...
Page 15: ...14 Model 300 2 S230...
Page 17: ...16...
Page 19: ...18...
Page 21: ...20...
Page 23: ...22...
Page 26: ...NOTES...