Systems and scheduled
maintenance
Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · [email protected]
33
Marine diesel engines. Operator’s manual
5.8.
Electrical system
Control Panel
You can find all
information related to the control panel in Control Panel Operator’s Manual of
your engine.
Sensors and switches
Coolant temperature sensor:
-
Operating voltage: 6-24V
-
Operating current: <85mA, Pmax<0.25W
-
Operating temperature: -40°C to +120°C
-
Measuring range: -40°C to +120°C
-
Absolute max. value: 130°C, max. 1 min.
-
Protection: BODY IP 67
-
Tightening torque: Max. 20Nm
Oil pressure sensor:
-
Operating voltage: 6-24V
-
Operating current: >20mA, <85mA, Pmax<0.25W
-
Operating temperature: -20°C to +100°C
-
Measuring range: 0
–
10 BAR
-
Absolute max. value: 30 BAR, max. 2 seconds.
-
Protection: BODY IP 67
-
Tightening torque: Max. 20Nm
Coolant temperature sensor specifications (two pole)
-
Operating voltage: 6-24V
-
Operating current: <85mA, Pmax<0.25W
-
Operating temperature: -40°C to +120°C
-
Measuring range: -40°C to +120°C
-
Absolute max. value: 130°C, max. 1 min.
-
Protection: BODY IP 67
-
Tightening torque: Max. 20Nm
Function table
Temperature
(ºC)
Resistance
(ohm)
Tolerance
(ohm)
40
287.4
±32.8
60*
134
±13.5
80
69.1
±6.5
90*
51.2
±4.3
100*
38.5
±3.0
120
22.7
±2.2
*Test point
Function table
Pressure
(BAR)
Resistance
(ohm)
Tolerance
(ohm)
0
10
+3/-5
2
52
±4
4
88
±4
6
124
±5
8
155
±5
10
184
+20/-10
Function table
Temperature
(ºC)
Resistance
(ohm)
Tolerance
(ohm)
40
287.4
±32.8
60*
134
±13.5
80
69.1
±6.5
90*
51.2
±4.3
100*
38.5
±3.0
120
22.7
±2.2