f ) Power limits
User can set the power limit here, the setting value is from 0.00-1.00.
g) Grid
Usually end user do not need to set the grid parameters. All default value
have been set before leaving factory according to safety rules.
If need to reset, any changes should according to the requirement of local
grid.
﹦﹦﹦
Power Limits
﹦﹦﹦
>Proportion
0.00
﹦﹦﹦
Grid
﹦﹦﹦
>Vac Upper
000.0
Parameter
Comment
Normally
Vac upper
Voltage high protect
Vac lower
Voltage low protect
Vac upper slow
Voltage high slow protect
Vac lower slow
Voltage low slow protect
Fac upper
Frequency high protect
Fac lower
Frequency low protect
Fac upper slow
Frequency high slow protect
Fac lower slow
Frequency low slow protect
Vac 10m avg
10 min voltage high protect
36
Operation Method
Operation Method
P(u) Function
>Enable/Disable
e)P(u) Function
The device is suitable for Australia if the “Enable” is chosen.
>Enable<
h) DRM Function
User can choose whether using the DRM function or not.
﹦﹦﹦
DRM Function
﹦﹦﹦
>Mode Select
Disable
37
j) Reset error logs
User can reset the error log here. Press up or down button to select and
press “OK” to confirm.
﹦ ﹦ ﹦
>Reset
No
k) Start guide
This interface makes user set initial setting of the inverter again possible.
﹦ ﹦ ﹦
Start Guide
﹦ ﹦ ﹦
Reset Error logs
﹦ ﹦ ﹦
>Start
l) Reset energy
User can reset the energy record here. Press up or down button to select and
press “OK” to confirm.
﹦﹦﹦
Reset Energy
﹦﹦﹦
>Reset
No
﹦﹦﹦
﹦﹦﹦