Troubleshooting
Decommissioning
7.2 Routine maintenance
Inverters do not need any maintenance or correction in most condition,but if
the inverter often loses power due to overheating,this can be the following
reason:
●
The cooling fins on the rear of house are covered by dirts.
Clean the cooling fins with a soft dry cloth or brush if necessary.
Only trained and authorized professional personnel who are familiar with the
requirements of safety was allowed to perform servicing and maintenance
work.
►
Safety checks
Safety checks should be performed at least every 12 months by manufacturer's
qualified person who has adequate training,knowledge,and practical experience
to perform these tests.The data should be recorded in an equipment log.If the
device is not functioning properly or fails any of test,the device has to be
repaired.For safety check details ,refer to this manual,section 2 Safety instruction
and EC Directives.
►
Maintain periodically
Only qualified person may perform the following works.
During the process of using the inverter,the manage person shall examine and
maintain the machine regularly.The concrete operations are follow.
1: Check that if the cooling fins on the rear of house are covered by dirts,
and the machine should be cleaned and absorbed dust when necessary.
This work shall be check time to time.
2: Check that if the indicators of the inverter are in normal state,check if the
keys of the inverter are in normal state,check if the display of the inverter is
normal.This check should be performed at least every 6 months.
3: Check that if the input and output wires are damaged or aged.This check
should be performed at least every 6 months.
4: You should get the inverter panels cleaned and their security checked at
least every 6 months.
8. Decommissioning
8.1 Dismantling the Inverter
Disconnect the inverter from DC Input and AC output.
Wait for 5 minutes for de-energizing.
Disconnect communication and optional connection wirings.
Remove the inverter from the bracket.
Remove the bracket if necessary.
If possible, please pack the inverter with the original packaging.
If it is no longer available, you can also use an equivalent carton that meets
the following requirements.
Suitable for loads more than 30 kg.
With handle.
Can be fully closed.
8.3 Storage and Transportation
Store the inverter in dry place where ambient temperatures are always
between -20 °C - +60 °C.Take care of the inverter during the storage and
transportation,keep less than 4 cartons in one stack.
8.2 Packaging
When the inverter or other related components need to be disposed. Have
it carried out according to local waste handling regulations. Please be sure
to deliver wasted inverters and packing materials to certain site, which can
assist relevant department to dispose and recycle.
Warning!
Before dismantling the inverter, please be sure to disconnect the
DC switch, and then unplug the PV and AC cables, otherwise it
will lead to an electric shock hazard.