Troubleshooting

Decommissioning

7.2 Routine maintenance

Inverters do not need any maintenance or correction in most condition,but if 
the inverter often loses power due to overheating,this can be the following 
reason:

● 

The cooling fins on the rear of house are covered by dirts.

Clean the cooling fins with a soft dry cloth or brush if necessary.
Only trained and authorized professional personnel who are familiar with the 
requirements of safety was allowed to perform servicing and maintenance 
work.

► 

Safety checks

Safety checks should be performed at least every 12 months by manufacturer's 
qualified person who has adequate training,knowledge,and practical experience 
to perform these tests.The data should be recorded in an equipment log.If the 
device is not functioning properly or fails any of test,the device has to be 
repaired.For safety check details ,refer to this manual,section 2 Safety instruction 
and EC Directives.

Maintain periodically

Only qualified person may perform the following works.
During the process of using the inverter,the manage person shall examine and 
maintain the machine regularly.The concrete operations are follow.
1: Check that if the cooling fins on the rear of house are covered by dirts,
and the machine should be cleaned and absorbed dust when necessary.
This work shall be check time to time.
2: Check that if the indicators of the inverter are in normal state,check if the 
keys of the inverter are in normal state,check if the display of the inverter is 
normal.This check should be performed at least every 6 months.
3: Check that if the input and output wires are damaged or aged.This check 
should be performed at least every 6 months.
4: You should get the inverter panels cleaned and their security checked at 
least every 6 months.

8. Decommissioning 

8.1 Dismantling the Inverter

 Disconnect the inverter from DC Input and AC output.
 Wait for 5 minutes for de-energizing.
 Disconnect communication and optional connection wirings.
 Remove the inverter from the bracket.
 Remove the bracket if necessary.

If possible, please pack the inverter with the original packaging.
If it is no longer available, you can also use an equivalent carton that meets 
the following requirements.
Suitable for loads more than 30 kg.
With handle.
Can be fully closed.

8.3 Storage and Transportation

Store  the  inverter  in  dry  place  where  ambient  temperatures  are  always 
between  -20  °C  -  +60  °C.Take  care  of  the  inverter  during  the  storage  and 
transportation,keep less than 4 cartons in one stack.

8.2 Packaging

When the inverter or other related components need to be disposed. Have 
it carried out according to local waste handling regulations. Please be sure 
to deliver wasted inverters and packing materials to certain site, which can 
assist relevant department to dispose and recycle.

Warning!

Before dismantling the inverter, please be sure to disconnect the 
DC switch, and then unplug the PV and AC cables, otherwise it 
will lead to an electric shock hazard.

Summary of Contents for X1-6.0-T-D

Page 1: ...nual belongs to SolaX Power Network Technology Zhe jiang Co Ltd Any corporation or individual should not plagiarize partially or fully copy including software etc and no reproduction or distribution of it in any form or by any means All rights reserved SolaX Power Network Technology Zhe jiang Co Ltd reserves the right of final interpretation ...

Page 2: ...rter 3 3 Dimension 4 Technical Data 4 1 DC Input 4 2 AC Output 4 3 Efficiency Safety and Protection 4 4 General Data 5 Installation 5 1 Check for Transport Damage 5 2 Packing List 5 3 Installation Precaution 5 4 Installation Steps 5 5 Connection of the Inverter 5 6 Run the Inverter 6 Operation Method 6 1 Control Panel 6 2 LCD Function 6 3 LCD Operation Contents 01 03 03 03 03 04 04 06 09 10 11 11 ...

Page 3: ...Symbols Used The following types of safety instructions and general information appear in this document as described below Danger Danger indicates a hazardous situation which if not avoided will result in death or serious injury Warning Warning indicates a hazardous situation which if not avoided could result in death or serious injury Caution Caution indicates a hazardous situation which if not a...

Page 4: ...ween the inverter and the PV generator if the voltage protection level VP of the surge arresters is greater than 1100V an additional SPD type 3 required for surge protection for electrical devices To protect the AC system surge suppression devices SPD type2 should be fitted at the main incoming point of AC supply at the consumer s cutout located between the inverter and the meter distribution syst...

Page 5: ...ing wiring is in good condition and that wire is not undersized Do not disassemble any parts of inverter which are not mentioned in installation guide It contains no user serviceable parts See Warranty for instructions on obtaining service Attempting to service the X1 Series inverter yourself may result in a risk of electric shock or fire and will void your warranty Keep away from flammable explos...

Page 6: ...el Symbols on the Inverter Symbol Explanation Operating Display Communication is active An error has occurred please inform your installer immediately Symbols on the Type Label Symbol Explanation CE mark The inverter complies with the requirements of the applicable CE guildlines RCM remark SAA certification Beware of hot surface The inverter can become hot during operation Avoid contact during ope...

Page 7: ... upon installing and configuring system correctly including using the specified wires The system must be installed only by professional assemblers who are familiar with requirements for safety and EMC The assembler is responsible for ensuring that the end system complies with all the relevant laws in the country where it is to be used The individual subassembly of the system shall be interconnecte...

Page 8: ...al AC Connector B C D E F G Description Waterproof Valve 12 13 Introduction Technical Data Model Model 45 0 37 3 1 0 8 leading 0 8 lagging single phase Max output overcurrent protection A Max inverter backfeed current to the array mA optional 401mm 450mm 213mm RS 485 NFI DRM optional 3000 4000 550 360 100 500 11 22 12 24 120 2 X1 6 0 T N X1 6 0 T D 550 X1 7 0 T N 3000 5000 360 100 500 11 22 12 24 ...

Page 9: ...100 non condensing 2000 IP65 Transformerless Ⅰ 1w Ⅲ MAINS Ⅱ PV Ⅱ External natural wind Internal intelligent fan 40dB Non isolated RS485 NFI optional DRM WIFI GPRS LAN USB Standard 5 years 10 years optional 5 Installation 5 1 Check for Transport Damage 5 2 Packing List Make sure the inverter is intact during transportation If there are some visible damages such as cracks please contact your dealer ...

Page 10: ... Step 2 Match the inverter with wall bracket Ø Ø Ø Below tools are needed before installation Installation tools crimping pliers for binding post and RJ 45 screwdriver manual wrench and Φ10 driller a Use the wall bracket as a template to mark the position of the 4 holes on the wall b Drill holes with driller make sure the holes are deep enough at least 50mm for installation and then tighten the ex...

Page 11: ...Trip 7mm of insulation from the wire end d Separate the DC connector as below d Separate the DC connector as below e Insert striped cable into pin contact and ensure all conductor strand are captured in the pin contact f Crimp pin contact by using a crimping pliers Put the pin contact with striped cable into the corresponding crimping pliers and crimp the contact torque 1 2 0 1Nm g Insert pin cont...

Page 12: ... Connection between Load and Inverter Cable Micro breaker d Separate the AC plug into three parts as below Hold the middle part of the female insert rotate the back shell to loose it and detach it from female inset Remove the cable nut with rubber insert from the back shell e Slide the cable nut and then back shell onto the cable f Insert the tripped end of each three wires into the appropriate ho...

Page 13: ...not provided galvanic isolation from the mains to the PV array feedback current to the array is 0A 250VAC for 6 0KW 7 0KW 8 0KW based on the fuse provided in the mains Also in the worst case the reverse current comprises the sum of the short circuit currents of all intact lines Therefore the current carrying capacity of the components and sub assemblies provided in the end use system connectors ca...

Page 14: ...he waterproof connector with RJ45 then insert it into the RJ45 connector following the PIN definition rule 4 Crimp the RJ45 connector with the crimping plier 5 Insert the cable into the RS 485 NFI port of the inverter and tighten the waterproof connector DRM is provided to support several demand response modes by giving control signals as below 1 8 c DRM 24 25 Installation Installation PIN Definit...

Page 15: ...h fault alarm is the additional detection as required by AS 4777 2 and AS NZS 5033 it will give an alarm once the earth impedance of the PV arrays is less than 30KΩ Earth Fault Alarm Optional 26 27 Installation Installation 5 After the upgrade is complete please remember to turn off the DC switch or disconnect the PV connector then pull off the U disk screw the waterproof lid Note Vx xx is version...

Page 16: ... which means inverter starting Waiting Inverter is waiting to checking when DC input voltage from panels is greater than 100V lowest start up voltage but less than 150V lowest operating voltage Checking Inverter will check DC input environment automatically when DC input voltage from the PV panels exceeds 150V and PV panels have enough energy to start inverter Normal Inverter begins to operate nor...

Page 17: ...s the power generated within the day Normal shows the status of the inverter Menu interface The menu interface is a transfer interface for user to get into other interface to finish the setting or getting the information User can get into this interface by pressing OK button when LCD displays the main interface User can select interface by moving the cursor with function button and press OK to con...

Page 18: ... 0 0 Safety country AS4777 Setting Safety Date Time New Password a Safety The user can set the safety standard here According to different countries and grid tied standards There is 2 standards for choice May change without notice b Solar This status shows the real time PV condition of the system such as input voltage current and power situation of each PV input Press up and down button to review ...

Page 19: ...Excited PF p Q u Fixed Q Power Mode Comment Off Under Excited PF value Over Excited PF value PF p Upper limit Lower limit Power Upper Power Lower Q u QuVupRate QuVlowRate Reactive power control Reactive standard curve cos φ f P For VDE ARN 4105 curve cos φ p should refer to curve A default values of setting are as shown in curve A For E 8001 curve cos φ f P should refer to curve B default values o...

Page 20: ...quency low protect Fac upper slow Frequency high slow protect Fac lower slow Frequency low slow protect Vac 10m avg 10 min voltage high protect 36 Operation Method Operation Method P u Function Enable Disable e P u Function The device is suitable for Australia if the Enable is chosen Enable h DRM Function User can choose whether using the DRM function or not DRM Function Mode Select Disable 37 j R...

Page 21: ...e items About This interface shows information of the inverter include product SN register SN machine type master DSP1 slave DSP2 and manager Error log No error About Product SN 0123456 7 Troubleshooting 7 1 Trouble shooting This section contains information and procedures for solving possible problems with X1 series inverters and provides you with troubleshooting tips to identify and solve most p...

Page 22: ...er located in a clean dry adequately ventilated place Have the DC input breakers been opened Are the cables adequately sized and short enough Are the input and output connections and wiring in good condition Are the configurations settings correct for your particular installation Are the display panel and the communications cable properly connected and undamaged Contact Solax Customer Service for ...

Page 23: ...ter are in normal state check if the keys of the inverter are in normal state check if the display of the inverter is normal This check should be performed at least every 6 months 3 Check that if the input and output wires are damaged or aged This check should be performed at least every 6 months 4 You should get the inverter panels cleaned and their security checked at least every 6 months 8 Deco...

Page 24: ......

Reviews: