Fireplace Surround to L. Side Wall
6" (152mm)
Fireplace Surround to R. Side Wall
6" (152mm)
Fireplace Surround to Corner Wall
6" (152mm)
Vent Pipe to Adjacent Materials
1.5" (38mm)
Fireplace Surround to Ceiling
8" (203mm)
Fireplace Surround to Rear Wall
0" (0mm)*
Fireplace Surround to Floor
3" (76mm)**
MINIMUM CLEARANCES TO
COMBUSTIBLE CONSTRUCTION
CLEARANCES
Several issues must be addressed when selecting a
suitable location for your TWENTY6 fireplace. The
minimum clearances to combustible construction are
listed below. In addition, access to the gas supply must
be considered. The location of the fireplace will also
affect the venting requirements and you must be certain
the location will allow compliance with the venting
requirements shown on page 11. You must also insure
that your installation provides adequate accessibility
clearance for servicing and proper operation.
Installation and repair should be done by a licensed
service technician. The appliance should be inspected
before use and at least annually by a professional
service technician. More frequent cleaning may
be required due to excessive lint from carpeting,
bedding material, etc. It is imperative that the control
compartment, burners and circulating air passageways
of the appliance be kept clean.
NOTE: Alcove installation is not permissable.
A
A
B
B
E
WALLS
A = 6" (152 mm)
CORNER
B = 6" (152 mm)
(Shown with optional corner Kit)
AIR SPACE
E = 3/8" (9.5mm)
(Space behind the
Mounting Plate)
C
D
FLOOR
D = 3" (76 mm)
CEILING
C = 8" (203 mm)
F
MANTEL/SHELF
F = 8" (203 mm)