background image

SÓLAS

 CONTEMPORARY FIRE 

2

LIGHTING & OPERATION

FIRST FIRE INSTRUCTIONS 

When operating your new fireplace for the first time, some 

vapors may be released due to the curing compounds 

used in the manufacture of the appliance. They may cause 

a slight odor and could cause the flames to be the full 

height of the firebox, or even slightly higher, for the first few 

hours of operation. It is possible that these vapors could 

set off smoke detection alarms in the immediate vicinity. 

These vapors are quite normal on new appliances. We 

recommend opening a window to vent the room during the 

burn off period. After a few hours use, the vapors will have 

disappeared and the flames will be at their normal height.
It is important that the Comfort Blower is turned on to help 

clear the vapors from the unit. 
Follow these instructions for a successful first fire;

1.

  Turn the fireplace on in Manual Mode.

2.

  Set flame height to HI.

3.

  Set the Comfort Blower speed control to level 

4

.   Let the fireplace run for 

3 hours

 at this setting then shut 

off fireplace and let it cool.

5.

   After the fireplace cools, turn the fireplace on in manual 

mode with flame on HI and the Comfort Blower off.

6.

   Allow fireplace to run for 

6 hours

 in this setting.

NOTE: Slight Odors may still be noticed on future uses 

of the fireplace but will diminish over time. The type of 

finishing materials used around the fireplace may add 

odors or add to the curing time. If the fireplace has not 

been used in several months, it is normal for odors to 

occur caused by lint or dust that has settled on the unit 

while not in use.

FLAME SUPERVISION DEVICE 

For your safety, this appliance is fitted with a flame 

supervision device which will shut-off the gas supply if, for 

any reason, the pilot flame goes out. This device incorporates 

a fixed probe, which senses the heat from the pilot flame. If 

the probe is cool, the device will prevent any gas flow unless 

manually lighting the pilot. See full lighting instructions. 

NOTE: 

Periodically conduct a visual check to ensure the 

pilot and burner flames are as shown (top of page 3). 
During extreme cold weather, it is recommended that you 

leave the pilot running to prevent condensation forming in 

the firebox and on the glass viewing area during startup.

LIGHTING, OPERATION & RATING INFO  

The Lighting, Operation and Rating information is located 

on a plate in front of the Comfort Blower inside the front 

face of the fireplace.
To access the plate, remove lower air trim panel as shown 

in step 1 on page 26.

SERVICING  

If any attention is required for your appliance, contact your 

dealer quoting the model number and serial number. This 

number is on the rating plate, which is located adjacent 

to the control module. The replacement parts are shown 

at the end of this manual. Please always quote the part 

number and description when requesting spare parts. 

Warranty is void if serviced by a non-qualified technician.

FIREPLACE CONTROL DEVICES

There are two ways to control your fireplace.
1. SÓLAS One-Touch Remote 

(S-507)

2.  Optional Wall Touch Pad 

(WTP-1500) 

The SÓLAS One-Touch Remote can be programmed to 

function automatically—see pages 34-38.
The Optional Wall Touch Pad can be used to turn the flame 

on, off, and to increase or decrease the flame height.

NOTE: The SÓLAS One-Touch Remote in the 

AUTO mode will override the Wall Touch Pad.

NOTE: The Wall Touch Pad is not compatible 

with the SÓLAS Self-Calibrating Power Vent 

System.

 

UP

DOWN

ON-OFF

PM

AM

SÓLAS One-Touch 

Remote 

Part #S-507

Wall Touch Pad 

Part #WTP-1500 

(Optional)

Summary of Contents for One-Touch Remote

Page 1: ...ake great pride in every fireplace we make with every product being fully tested throughout the production process to ensure your safety and warmth throughout the years Sincerely The SÓLAS Team SUPPLEMENTAL MANUAL Your Fireplace has been equipped with the SÓLAS next generation control system Please refer to this supplemental manual for operation of the SÓLAS One Touch Remote ONE TOUCH REMOTE ...

Page 2: ...ame supervision device which will shut off the gas supply if for any reason the pilot flame goes out This device incorporates a fixed probe which senses the heat from the pilot flame If the probe is cool the device will prevent any gas flow unless manually lighting the pilot See full lighting instructions NOTE Periodically conduct a visual check to ensure the pilot and burner flames are as shown t...

Page 3: ...t automatically lights the pilot Do not try to light the pilot by hand 3 Using the Remote or the optional Wall Touch Pad push the ON OFF button until you hear an audible signal to insure the appliance is off 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don t smell gas proceed to step 5 5...

Page 4: ...s and hold the Control Module s RESET button until you hear one short beep and one long beep After the second beep release the reset button 5 Within the subsequent 20 seconds press and hold the button on the Remote for 2 3 seconds will be displayed and flash on the Remote during the pairing sequence The Remote will count up from 1 to 8 and you will hear two short beeps confirming the pairing is co...

Page 5: ...e breaker Automatic Shut Off in certain conditions Your fireplace s Remote is equipped with an automatic shut off mechanism which is activated in certain conditions See page 38 in the Remote Control Operation section for a description of this feature NOTE Before using the remote control system for the first time the Control Module and the Remote are synchronized at the factory See the section SÓLA...

Page 6: ...ld Proof Light not used Comfort Blower Program Mode Temperature Time Auxiliary Feature not used Countdown Timer Battery Status Split Flow Mode not used F or C DO NOT leave the Remote on the hearth mantel or on top of the fireplace Use the Remote wall mount holder provided ONE TOUCH REMOTE MAIN DISPLAY OVERVIEW ...

Page 7: ...ilot does not stay lit after several tries call your local service technician or gas supplier TO TURN OFF FIRE Press to turn OFF When the pilot is off it will take 2 minutes before it can be lit again NOTE There is a 2 minute delay after switching off before the next ignition is possible CAUTION Always check the fire and pilot visually to ensure they are off FLAME HEIGHT ADJUSTMENT To increase fla...

Page 8: ...hold simultaneously 2 disappears Child Proof is now inactive and the Remote has full function COUNTDOWN TIMER You can set your fireplace to automatically turn off at the end of a timer To set a Countdown Timer 1 Press and hold until is displayed Hour flashes 2 Press or to select Hour 3 To confirm press Minutes flash 4 Press or to select Minutes 5 To confirm press or wait To turn off a Countdown Ti...

Page 9: ...erature for Thermostatic Mode is the temperature for the ON time in Program Mode Changing the Thermostatic Mode set temperature also changes the ON time temperature in Program Mode Default Settings ON TIME Thermostatic TEMPERATURE 70 F 21 C OFF TIME TEMPERATURE pilot flame only Temperature Setting 1 Press and hold until flashes ON and set temperature set in Thermostatic Mode is displayed 2 To cont...

Page 10: ...te This could cause a short circuit NOTE The batteries in your SÓLAS One Touch remote control and control module are to be replaced annually Only use brand name alkaline batteries such as Duracell or Energizer Remote The battery icon will show when the battery needs to be replaced Replace with two 1 5 V AAA alkaline batteries Control Module Frequent beeps for 3 seconds when the motor turns indicat...

Page 11: ...3 failed ignition sequences F06 shown No gas supply Air in pilot supply line No spark Reversed polarity in thermocouple wiring F06 F06 4 seconds 3 failed ignition sequences in 5 minutes Fire is not responding no pilot flame No gas supply Air in pilot supply line No spark Reversed polarity in thermocouple wiring Incorrect pilot orifice if valve has been converted from LPG to NG or vice versa F07 Lo...

Page 12: ...OSING solasfires com We recommend that our gas hearth products be installed and serviced by professionals who are certified in the U S by the National Fireplace Institute NFI as NFI Gas Specialists www NFIcertified org ...

Reviews: