background image

Amphenol Helios H4 

Connectors

Amphenol UTX H4 

Connectors

Approved connectors / Zugelassene steckverbinder / Conectores aprobados / Connettori approvati / Connecteurs approuvés

= 368 mm (14.5 in)

F

min

 = - 3.1 kN/m² (- 64 psf)

= 285 mm (11.2 in)

F

min

 = - 3.1 kN/m² (- 64 psf)

= 150 mm (5.9 in)

F

min

 = - 1.1 kN/m² (- 23 psf)

= 419 mm (16.5 in)

F

max

 = + 5.4 kN/m² (+ 113 psf)

= 498 mm (19.6 in)

F

max

 = + 3.1 kN/m² (+ 64 psf)

= 250 mm (9.8 in)

F

max

 = + 1.4 kN/m² (+ 29 psf)

= 285 mm (11.22 in)

F

min

 = - 2.4 kN/m² (- 50 psf)

= 10 mm (0.4 in)

F

min

 = - 1.4 kN/m² (- 30 psf)

= 10 mm (0.4 in)

F

min

 =- 1.3 kN/m² (- 27 psf)

= 498 mm (19.61 in)

F

max

 = + 4.4 kN/m² (+ 92 psf)

= 70 mm (2.8 in)

F

max

 = + 1.6 kN/m² (+ 33 psf)

= 250 mm (9.8 in)

F

max

 = + 1.4 kN/m² (+ 29 psf)

= 150 mm (5.9 in)

F

min

 = - 1.1 kN/m² (- 23 psf)

= 797 mm (31.4 in)

F

min

 = - 2.4 kN/m² (- 50 psf)

= 250 mm (9.8 in)

F

max

 =  + 8.5 kN/m² (+ 178 psf)

= 797 mm (31.4 in)

F

max

 = + 2.4 kN/m² (+ 50 psf)

Fig. A

Fig. D

Fig. B

Fig. E

Fig. C

7

Summary of Contents for Sunmodule SWA XL mono Series

Page 1: ...7 www solarworld usa com Benutzerinformation User Instructions Indicaciones para el usuario Informazioni per l utente Informations pour l utilisateur 2017 08 01 XL 1 14 29 0 43 11 1 30 33 Rahmen Frame...

Page 2: ...den technischen Anforderungen des Gesamtsy stems entspricht Durch andere Anlagenkomponenten d rfen keine sch digenden mechanischen oder elektrischen Einfl sse auf das Modul ausge bt werden Module k nn...

Page 3: ...e high quality extruded aluminum or stainless steel clamps or stamped stainless steel clamps Insure that the mounting system and clamps meet the design requirements of the system In regards to Top Dow...

Page 4: ...inarse cuando tienen la misma intensidad el ctrica y conectados en paralelo solo se pueden combinar si tienen la misma tensi n Los m dulos no deben funcionar con una tensi n mayor que la permitida en...

Page 5: ...re sottoposti ad una tensione superiore a quella autorizzata per il sistema L apertura posta all interno dell angolo della cornice serve per lo scarico dell acqua e perci non deve essere chiusa Si con...

Page 6: ...i e Veillez ce que le panneau r ponde aux exigences techniques du syst me tout entier Les autres composants de l installation ne devraient produire aucun effet nocif m canique ou lectrique sur le pann...

Page 7: ...ax 5 4 kN m 113 psf b 498 mm 19 6 in Fmax 3 1 kN m 64 psf b 250 mm 9 8 in Fmax 1 4 kN m 29 psf c 285 mm 11 22 in Fmin 2 4 kN m 50 psf c 10 mm 0 4 in Fmin 1 4 kN m 30 psf c 10 mm 0 4 in Fmin 1 3 kN m 2...

Page 8: ...4 USA Tel 1 503 844 3414 Toll Free 1 855 467 6527 Fax 1 503 844 3403 customersupport solarworldusa com www solarworld usa com Revision Date Description 1 2017 08 30 Updated model names contact informa...