DaNGer!

electric shock

The connection of several modules in series results in the adding up of voltage 

and imposes danger. Do not insert electrically conducting parts into connectors! 

Do not fit solar modules and wiring with wet connectors! Make sure to work 

with dry tools and under dry working conditions!

Work on live parts

When working on wiring, use and wear protective equipment (insulated tools, 

insulated gloves, etc.)!

aTTeNTION

Do not use damaged modules. Do not dismantle modules Do not remove any 

parts or nameplates fitted by the manufacturer. Do not apply paint or adhesives 

on the back side, nor work on it with sharp objects.

WarNING!

arcing

Modules generate direct current (DC) when exposed to light. When breaking a 

closed circuit, a dangerous arc may be generated. Do not cut any live wires. 

Safe installation

Do not carry out installation work in strong winds. Secure yourself and other 

persons against falling. Secure work materials against dropping. Ensure a safe 

working environment so as to prevent accidents. 

fire protection/explosion protection

Modules must not be installed in the vicinity of highly flammable gases, vapors 

or dusts (e.g. filling stations, gas tanks, paint spraying equipment). The safety 

instructions for other system components must also be followed. Make sure to 

comply with local standards, building regulations and accident prevention regu-

lations during installation. For roof installation, modules must be mounted on a 

fire-resistant base material. 

Unpacking and intermediate storage

Do not use the junction box as a handle. Do not place modules roughly on hard floor 

or on their corners. Do not place modules on to of each other. Do not step or stand on 

modules. Do not place any objects on modules. Do not work on modules with sharp 

objects; store modules in a dry place. 

Grounding of module and frame

We recommend ensuring the functional grounding of the module metal frame. If 

an exterior lightning protection system is already provided, the PV system has to be 

integrated into the protection concept against direct lightning stroke. Local stan-

dards shall be observed.

Grounding in the US and Canada

The modules can be connected to the grounding holes using a lay-in lug and a sok-

ket head cap screw. We recommend using the components as listed below. Any PV 

grounding method and components complying with the NEC are also acceptable in 

the US and Canada.

Suitable ambient conditions

The module is intended for use in moderate climatic conditions. The module must 

not be exposed to focused light. The module must neither be immersed in water 

nor be exposed to continuous wetting (e.g. by fountains). Exposure to salt or sulfur 

(sulfur sources, volcanoes) implies a risk of corrosion. The module must not be used 

for maritime (e.g. boats) or automotive (vehicles) purposes. The module must not be 

exposed to extraordinary chemical loads (e.g. emissions from manufacturing plants). 

If the modules are installed on stables, a distance of 3.28 ft (1 m) to ventilation ope-

nings shall be ensured; apart from this, the modules shall not be used as a direct roof 

panel on stables.

appropriate installation situation

Make sure that the module meets the technical requirements of the overall system. 

Other  system  components  should  not  exert  any  adverse  mechanical  or  electrical 

influences  on  the  module.  Modules  may  bend  under  high  loads.  For  this  reason, 

sharp-edged fixing elements or other sharp objects (e.g. cable ties on mounting sec-

tions must not be mounted near the module back side. For connection in series, only 

modules of the same amperage rating, for connection in parallel, only modules of 

the same voltage ranging may be used. The modules must not be operated at a hig-

her voltage than the permissible system voltage. The inside opening of the frame 

corner element is intended for water drainage and must not be closed. For system 

documentation, please note the serial numbers.

Optimum installation

In  order  to  avoid  performance  losses,  all  modules  connected  in  series  should  be 

arranged with the same orientation and tilt angle. The modules should be installed 

in  an  all-season  shadow-free  area.  Even  partial  shadowing  results  in  yield  losses 

and is to be avoided. Ventilation of the module back side will prevent heat build-up 

adversely affecting performance.

Mounting

The modules must be securely fixed at a minimum of 4 locations on the substruc-

ture. Fixing is only allowed in designated areas. These designated areas for fixing 

are located on the module long sides. They are located between 1/8 of the module 

length and 1/4 of the module length, measured from the module corner. Fixing the 

module on its narrow sides is not sufficient. As regards clamping the modules from 

the front, the clamping area on the module frame must be at least 130 mm² for each 

fixing point. The required clamping force is 100 N/mm². Do not drill any holes into the 

module. Use corrosion-proof fixing material. 

electrical connection

The modules are provided with factory-assembled cables and connectors . Do not 

open the junction box in any case. Connectors may only be connected under dry con-

ditions. Make sure to avoid gaps in a plugged connection. Only singlecore solar cables 

with an adequate cross-section (4 mm² minimum) and appropriate connectors may 

be used for connecting the modules. Cables should be attached to the installation 

system  by  means  of  UV-resistant  cable  ties.  Exposed  cables  should  be  protected 

against sunlight and damage by suitable precautions (e.g. conduits) In order to limit 

voltages released by indirect lightning shock, the area of all conductor loops must 

be reduced to a minimum. Check that wiring is correct (polarity!) prior to starting 

the generator. 

Cleaning

On  principle,  the  modules  do  not  need  any  cleaning  if  the  tilt  angle  is  sufficient  

(> 15°; self-cleaning by rain). In case of heavy contamination, we recommend cleaning 

the modules with plenty of water (hose) without the addition of cleaning agents but 

application of a soft cleaning device (sponge). Never scrape or rub off dirt; this may 

result in micro-scratches.

 

Maintenance

We recommend regular inspections of the system to ensure that:

1.  All fixtures are securely tightened and corrosion-free;

2. Wiring is securely connected, properly arranged and free of corrosion;

3. Cables are free of damage;

Please also observe applicable standards. 

Disclaimer of liability

SolarWorld  AG  does  not  guarantee  the  operational  capability  and  functionality 

of  modules  if  the  instructions  contained  in  the  present  user  information  are  not 

complied with. Since compliance with this guide and the conditions and methods 

of installation, operation, use and maintenance of the modules are not checked or 

monitored by SolarWorld AG, SolarWorld AG accepts no liability for damage arising 

through improper use or incorrect installation, operation, use or maintenance. Fur-

thermore, liability for infringements of patent law or of other third party rights ari-

sing from the use of the modules is excluded unless we are automatically liable by 

law.

EN

Table: recommended components for grounding in the US and Canada

Item

Manufacturer/Description

Tightening torque

Lay-In lug

Ilsco GBL-4DB (E34440)

35 Ibf-in, 4-6 AWG str

25 Ibf-in, 8 AWG str

20 Ibf-in, 10-14 AWG sol/str

Socket head cap screw

10-24, 5/8", SS 18-8

62 Ibf-in (7.0 Nm)

Underwriters Laboratories Information (U.S. and Canada)

The solar module electrical characteristics are /-10% of the module label indi-

cated values of Isc , Voc and Pmpp under Standard Test Conditions (irradiance of 100 

mW/cm

2

, AM 1.5 spectrum, and a cell temperature of 25°C/77°F). Under normal con-

ditions, a photovoltaic module is likely to experience conditions that produce more 

current and/or voltage than reported at standard test conditions. Accordingly, the 

values of Isc and Voc marked on this module should be multiplied by a factor of 1.25 

when determining component voltage ratings, conductor capacities, fuse sizes, and 

size of controls connected to the PV output. Refer to section 690-8 of the Natio-

nal Electric Code (NEC) for an additional multiplying factor of 125% (80% de-rating) 

which may be applicable.  Over-current protection shall be in accordance with the 

requirements  of  Article  240  of  the  NEC.  Conductor  recommendations:  8-14  AWG 

(1.5-10 mm2) USE-2 (nonconduit)/ THWN-2 (conduit ), 90°C wet rated. Cable conduits 

should be used in locations where the wiring is accessible to children or small ani-

mals. Modification or tampering of diodes by unqualified personnel is not permit-

ted. Please consult a SolarWorld Service Center for additional information regarding 

diode replacement/repair. 

To reduce the operating temperature the module has to be mounted on any surface 

with a minimum distance of 4 inches (10 cm).

In Canada the installation shall be in accordance with CSA C22.1, Safety Standard for 

Electrical Installations, Canadian Electrical Code, Part 1.

Summary of Contents for Sunmodule Plus SW xxx Compact mono series

Page 1: ...suario Informazioni per l utente Informations pour l utilisateur Gebruikersinformatie Informace pro u ivatele Sunmodule Plus SW xxx poly Sunmodule Plus SW xxx Compact poly Sunmodule Plus SW xxx mono S...

Page 2: ...infl sse auf das Modul ausge bt werden Modu le k nnen sich bei hohen Belastungen durchbiegen Deswegen d rfen nahe der Modulr ckseite keine scharfkantigen Befestigungselemente oder andere spitze Gegens...

Page 3: ...ixed at a minimum of 4 locations on the substruc ture Fixing is only allowed in designated areas These designated areas for fixing are located on the module long sides They are located between 1 8 of...

Page 4: ...as para la fijaci n se encuentran en los lados largos del m dulo y oscilan entre 1 8 y 1 4 de la longitud del m dulo distancia medida desde la esquina del mismo No basta con la fijaci n en los lados c...

Page 5: ...etti appuntiti ad es fascette stringicavo sui profili di montaggio Per il collegamento in serie si possono impiegare solo moduli fotovoltaici con lo stesso amperaggio per il collegamento in parallelo...

Page 6: ...Chaque panneau doit tre fix de mani re s re sur la sous construction sur quatre points au minimum La fixation ne doit se faire que dans les zones pr d termin es Ces zones de fixation se trouvent sur l...

Page 7: ...eprofielen te monteren Bij seriescha keling mogen slechts modules met dezelfde stroomsterktes worden gebruikt bij parallelschakeling zijn dit alleen modules met dezelfde spanning Het is niet toe gesta...

Page 8: ...8 1 4 130 mm 100 N mm2 4 mm 15 1 2 3 SolarWorld AG SolarWorld AG SolarWorld AG GR Ilsco GBL 4DB E34440 35 Ibf in 4 6 AWG str 25 Ibf in 8 AWG str 20 Ibf in 10 14 AWG sol str E 10 24 5 8 SS 18 8 62 Ibf...

Page 9: ...ze moduly stej n intenzity elektrick ho proudu p i paraleln m zapojen pouze moduly se stejn m nap t m Moduly se nesm j provozovat s vy m nap t m ne je p pustn nap t syst mu Otvor uvnit rohu r mu slou...

Page 10: ......

Page 11: ......

Page 12: ...38 210050 Fax 33 4 38 210059 service solarworld fr www solarworld fr SolarWorld Americas LLC 4650 Adohr Lane Camarillo CA 93012 USA Phone 1 805 388 6200 Fax 1 805 388 6395 service solarworld usa com w...

Reviews: