6.7 Installation of the roof top enclosure frame
After attaching all side module connections and the ca-
bling, the roof enclosure frame on the top module fi eld
edge is now installed. Please consult the installation in-
structions of the respective manufacturer.
7
The principle of rear ventilation
In combination with a properly designed roof construc-
tion, the EasyIn system guarantees optimal ventilation at
the rear of the roof surface. Air inlets located in the eaves
allow (e.g. through bird guards) ambient air to fl ow in-
wards between the EasyIn System and the roof sub-con-
struction.
As the air heats up it rises due to its lower density, and es-
capes through the ventilation openings at the roof's ridge
or the ventilation tiles to be attached. Colder air (with
higher density) is sucked in from below to compensate
the pressure diff erence resulting from cold/warm air tran-
sition. This natural convection (=chimney eff ect) ensures
that the SOLARWATT EasyIn system is cooled suffi ciently
guaranteeing optimum performance even at high tem-
peratures.
Figure 41 (Principle illustration)
A Cold air fl ow
B Warm air fl ow
C Rafters with sarking membrane and counter battens
D Lower enclosure frame
E EasyIn Module
F Upper enclosure frame
G Supporting board 98 x 20 mm
H Attachment angle
Roof battens
Aluminum guide rail
Cold air » High density
Pr
es
sur
e c
ompensation » Driving
pr
es
sur
e
Hot air » Lo
w density
A
B
C
D
E
F
H
G