Then fi t the respective left and right edge module in the
topmost module row with the
top-long module connec-
tion (6 holes)
. These connections must each be mount-
ed and staggered respectively to the outer module fi eld
edge. The modules lying in between receive the
top-short
module connection (3 holes)
, which is laid out centrally
to the modules.
Press on the top module connections until they are
“locked” onto the transverse seal and module edge then
screw these in each with 3 metal sheet cutting screws 5.5
x 35.
Now install the side roof enclosure frame.
When using the SOLARWATT roofi ng frame please consult
the installation instructions for the roofi ng frame.
Figure 36
NOTE
For your own roof enclosure frame you will fi nd design proposals in Chapter 9.5.
NOTE
NOTE
NOTE
6.5 Side module connection
After the roof side enclosure frames (grooves) have been
mounted, the side module connections on the long sides
of the edge modules are attached.
To this end, on the side module connections for the low-
est module row, their lower ends generally need to be
adapted to the roof groove by separating a correspond-
ingly narrow strip from the module connections.
Start by attaching the lower row of the module fi eld re-
spectively to the lower edge of the module and then work
your way upwards.
Figure 37
Cut for adaptation to roof-side gutters in lowest module
row