14
3.3.1 Multi MPPT operation mode
In the multi MPPT operating mode each power unit operates its own MPP tracker, allowing
the connection of as many as three mutually independent PV generators to each TS-SV
inverter.
Station with three TS-SV inverters in the multi MPPT operating mode
TS-SV
3
3
PU1
PU2
PU3
PU1
PU2
PU3
TS-SV
TS-SV
PU1
PU2
PU3
ModularBus
ModularBus
3
MCU
DC input
1
DC input
2
DC input
3
DC input
4
DC input
5
DC input
6
DC input
7
DC input
8
DC input
9
MV transformer
AC output
For this variant, the MCU assumes the master control of the TS-SV inverter, and also
acts as a joint user interface and enables the integration of the station into a MaxComm
communications network.