4. Appendix

 

 
RDM

 

F

UNCTIONALITY

 

 

Mozart power supplies have RDM Functionality.  Below are the RDM functions available in these devices.  
TMB has many options for RDM control of your devices:  ProPlex RDMigo and IQ RDM Manager Software; 
ProPlex Striker; and ProPlex MasterFade.  Additionally, ProPlex RDM Opto-Splitters and the ProPlex IQ 
product range offer many means of RDM over DMX data distribution. 
 

 

Main 

Display 

Voltage (V) 

Current (A) 

Mode 

Display invert 

Present value 

Present value 

DMX address 

Display level 

Highest value 

Highest value 

RDM version 

 

Lowest value 

Lowest value 

Software version 

 

 

 

 

 

G

ENERAL 

M

AINTENANCE

 

 

To maintain optimum performance and minimize wear fixtures should be cleaned frequently.  Usage and 
environment are contributing factors in determining frequency.  As a general rule, fixtures should be 
cleaned at least twice a month.  Dust build up reduces light output performance and can cause 
overheating.  This can lead to reduced lamp life and increased mechanical wear. Be sure to disconnect 
power to the fixture before conducting maintenance. 
 
Unplug fixture from power.  Use a vacuum or air compressor and a soft brush to remove dust 
collected on external vents and internal components.  Clean all glass when the fixture is cold with a mild 
solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply solution to 
the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical surfaces until they 
are free of haze and lint. 
 
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to 
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, 
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics.  Clean 
with soft cloth using normal glass cleaning fluid.  Always dry the parts carefully.  Clean the external optics 
at least every 20 days. Clean the internal optics at least every 30 to 60 days. 
 
 
 

L

IMITED 

W

ARRANTY

 

 

Solaris LED fixtures (the Product) are warranted by TMB against defective materials or workmanship 
for a period of two (2) years from the date of original sale by TMB.  
 
TMB’s warranty shall be restricted to the repair or replacement of any part that proves to be defective 
and for which a claim is submitted to TMB before the expiration of the applicable warranty periods.  
 
This Limited Warranty is void if the defects of the Product are the result of:  

 

Opening the casing, repair, or adjustment by anyone other than TMB or persons specifically 
authorized by TMB  

 

Accident, physical abuse, mishandling, or misapplication of the product.  

 

Damage due to lightning, earthquake, flood, terrorism, war, or act of God.  

 

Summary of Contents for mozart

Page 1: ...USER MANUAL TMB 24 7 Technical Support US Canada 1 818 794 1286 Toll Free 1 877 862 3833 877 TMB DUDE UK 44 0 20 8574 9739 Toll Free 0800 652 5418 e mail techsupport tmb com...

Page 2: ...G RIGGING 10 WAY PSU 4 2 SETUP 5 DMX CONNECTOR CONFIGURATION FOR MOZART 10 WAY PSU 5 SETTING UP A DMX SERIAL LINK 6 FIXTURE LINKING 6 3 OPERATING INSTRUCTIONS 7 PIXEL MAP 7 INTERNAL ADDRESS SET 8 RDM...

Page 3: ...ixture carefully unpack the carton and check the contents to ensure that all parts are present and in good condition Notify the shipper immediately and retain packing material for inspection if any pa...

Page 4: ...nit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact your distributor FUSE REPLACEMENT The Mozart 10 way PSU uses a 6A 250V sl...

Page 5: ...32 devices should be connected on one data link Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digita...

Page 6: ...le 5 pin connector of the DMX console 2 Connect the opposite end of the cable female to the input connector of the Mozart PSU consisting of a male 5 pin connector 3 Proceed to connect from the PSU out...

Page 7: ...gines which are located in 8 rows and 8 columns There are 3 control modes for Solaris Mozart fixtures 1 As 1 pixel unit 3 channel mode 2 As 4 pixel unit 12 channel mode 3 As 16 pixel unit 48 channel m...

Page 8: ...0 way powersupply To set the fixture address of Mozart fixtures 1 10 follow these steps Press and hold Address set button located at the back of the Mozart The current internal addressing number will...

Page 9: ...Solaris Mozart user manual version 2 0 122216 9 Using a starting address of DMX 1 on the 10 way PSU this chart is an example of the Mozart fixture addresses...

Page 10: ...nt temperature of Mozart press Address set button located at the back of fixture If Mozarts temperature is below or equal 40 C 104 F one green pixel 4 LEDs will appear as shown Mozart s temperature is...

Page 11: ...ith a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens Gent...

Page 12: ...rNA tmb com 527 Park Ave San Fernando CA 91340 Tel 1 818 899 8818 Fax 1 818 899 8813 tmb info tmb com www tmb com RETURN PROCEDURE Returned merchandise must be sent prepaid and in the original packing...

Page 13: ...Sensor M12 LIGHT SOURCE LEDs 64 Cree LMC E LEDs Colors RGB Beam spread 120 Refresh reate 38 400Hz Average Color Wavelenght red 625 nm green 530 nm blue 460 nm THERMAL Max ambient temperature 40 C Min...

Page 14: ...ecified Power consumption 200W max with 10 Mozarts DMX power OUT connector Amphenol Sensor M12 DC power OUT 24V THERMAL Operating temperature 4 to 104 F 20 to 40 C Cooling Convection IP rating IP20 CO...

Reviews: