5.0 Maintenance

Solaria modules are virtually maintenance free. Following simple maintenance steps will ensure reliable production 

of DC electric power for the expected life of the product.

 

y

Inspect electrical and mechanical connections for safety and corrosion once every year.

 

y

Under most weather conditions, normal rainfall is sufficient to keep the module glass surface clean.

 

Š

Modules that are mounted at a small tilt angle will not self-clean as easily as modules that are mounted at 

large tilt angles. If dirt build-up becomes excessive, clean glass surface with water and soft cloth. Do not 

use harsh cleaning materials.

 

y

Cleaning the back surface of the module is not necessary for proper operation.

6.0 Disclaimer of Liability

 

y

Since the use of this Safety, Installation and Operation Manual and the conditions or methods of installation, 

operation, use and maintenance of the module are beyond The Solaria Corporation control, The Solaria 

Corporation does not assume responsibility and expressly disclaims liability for loss, damage, injury or expense 

arising out of or in any connection with such installation, operation, use or maintenance of the module.

 

y

The Solaria Corporation assumes no responsibility for any infringement of patents or other rights of third 

parties that may result from the use of the module. No license is granted by implication or otherwise under any 

patent or patent rights.

 

y

The information in this Manual is based on The Solaria Corporation knowledge and experience and is believed 

to be reliable; but such information, including the product specifications (without limitations) and suggestions, 

do not constitute a warranty, expressed or implied. The Solaria Corporation reserves the right to make changes 

to the product specifications or this manual without prior notice.

 

y

This document may be provided in multiple languages. If there is a conflict among versions, the English 

language version dominates.

7.0 Electrical Specifications

 

y

Please refer to the module datasheet for electrical specifications. Rated electrical characteristics are within 

10% of STC values. The datasheet is available at www.solaria.com.

Summary of Contents for PowerXT R-BD Series

Page 1: ...ions Manual Solaria Corporation All rights reserved Contents subject to change without notice SOL MAN 0002 Rev 09 12 2020 SAFETY INSTALLATION AND OPERATIONS MANUAL United States and Canada PowerXT R M...

Page 2: ...94538 USA solaria com contact Other Information Product information is subject to change without notice All trademarks are recognized as the property of their respective owners User documentation is...

Page 3: ...o change without notice SOL MAN 0002 Rev 09 12 2020 Power Unlocked by Design Table of Contents 1 0 Introduction 4 2 0 Safety Precautions 4 3 0 Electrical Installation 5 4 0 Module Mounting 7 5 0 Maint...

Page 4: ...time y Do not artificially expose additional high intensity sunlight directly on the module y Do not disconnect modules while under load y All installations must be performed in compliance with local...

Page 5: ...cting cables be double insulated flexible copper Cu conductors with a minimum rating of 90 C The cable size should be determined by the applicable codes but is recommended that this be no less than 4m...

Page 6: ...local authorities to determine the necessary system hardware grounding requirements y Module frames should be electrically connected to an earth ground for safety and protection from lightning in acco...

Page 7: ...d Tied Applications y Contact Solaria for appropriate grounding guidelines 4 0 Module Mounting The Solaria Limited Product Warranty is contingent upon modules being mounted in accordance to the requir...

Page 8: ...ts of the National Electrical Code ANSI NFPA 70 2014 2017 y Any module without a frame laminate shall not be considered to comply with the requirements of IEC UL 61730 unless the module is mounted wit...

Page 9: ...V module mountings are available and compatible with PowerXT In the absence of manufacturer s recommendations for clamp size Solaria recommends minimum clamp size of 40mm 1 57 Maximum Allowed Loading...

Page 10: ...AREA A CLAMP AREA B Front Load 5400Pa 2400Pa Rear Load 3600Pa 2400Pa 4 0in 101 6mm CLAMP AREA A 6 0in 152 4mm CLAMP AREA A 12 4in 315 7mm 11 4in 290 0mm 11 0in 279 4mm CLAMP AREA B 11 0in 279 4mm CLAM...

Page 11: ...48 inches and maximum cantilever of 17 inches Follow racking system manufacturer s recommendations for coupling clamps at the module corners torques and bonding methods For rail less systems maximum a...

Page 12: ...the module are beyond The Solaria Corporation control The Solaria Corporation does not assume responsibility and expressly disclaims liability for loss damage injury or expense arising out of or in an...

Page 13: ...e without notice SOL MAN 0002 Rev 09 12 2020 Power Unlocked by Design 8 0 Mechanical Dimensions PowerXT xxxR PX PowerXT xxxR BX y Nominal dimensions in millimeters and inches Not Drawn to Scale y 4x 4...

Page 14: ...ject to change without notice SOL MAN 0002 Rev 09 12 2020 Power Unlocked by Design PowerXT xxxR PD PowerXT xxxR BD y Nominal dimensions in millimeters and inches Not Drawn to Scale y 4x 4 5mm 0 18in G...

Page 15: ...PORATION ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SOLARIA CORPORATION IS PROHIBITED NOTES THE TOLERANCES AND DIMENSIONS ON THIS PAGE ARE FOR THE REFERENCE OF THE INSTAL...

Page 16: ...olaria Corporation All rights reserved Contents subject to change without notice SOL MAN 0002 Rev 09 12 2020 Power Unlocked by Design Solaria USA 45700 Northport Loop East Fremont CA 94538 United Stat...

Reviews: