13 Weatherman function
►
Open the 2 turnbuckles
1
and remove the lid
2
upwards.
►
Empty the ash container.
DANGER
- risk of fire due to hot ash self-igni-
ting. Only store removed ash in metal con-
tainers with a lid.
►
After replacing the emptied ash container, lock
the bar again by pulling it forwards.
►
Confirm the information message on the display
with OK
1
►
Press the
Ash container emptied
2
button (in the
selection menu
, ash container button).
Abb. 2-55
Ä
The counter for the ash container fill level is
reset to zero.
Note: Press button
3
to open the
Boiler cleaning sta-
tistics
screen (shows the time of the last 5 boiler clea-
ning operations).
14.1.2 Boiler cleaning - manual activities
Two ways to start with the boiler cleaning:
The burner is active
►
Switch the boiler off (press the
STOP
button
) and leave to cool.
The boiler is in
standby
status
►
Press the
STOP
button
, and if necessary let
the boiler cool down.
►
Press the
boiler cleaning
button
►
Carry out the following activities:
–
Check the stainless steel combustion grate for
wear
–
Check the stainless steel combustion grate
support
–
Check the combustion chamber for ash
14.1.2.1 Check the stainless steel combustion
grate for wear
In the event of advanced wear of the stainless steel
combustion grate, the spaces in the grate enlarge. A
seriously worn stainless steel combustion grate will
allow incompletely burned pellets to fall through.
Check this regularly when emptying the ash con-
tainer; if necessary, replace the stainless steel com-
bustion grate
Operation manual
pelletelegance
35