5 Use and operation
5.3.1 Output test heating circuit
The available electrical outputs can be switched
on/off directly using the button. Can be used to test
the function of individual components.
!
ATTENTION
- Only to be undertaken by qua-
lified personnel.
Abb. 2-8
Abb. 2-9
5.4 Customer menu
Abb. 2-10
1 Required boiler values
2 Vacuum output
4 User lock
5 Message log
[2]
: Recording of alarm and noti-
fication messages
6 Operating hour counter
7 Output test boiler (CAUTION, only to be under-
taken by qualified personnel).
8 Qualified personnel menu
[2] Button is only visible if a message is active.
5.4.1 Required boiler values
Abb. 2-11: Required boiler values
Burner release time
1
The burner can start within the release times; outside
of these times, starting does not take place and/or the
burner is stopped. A time release from 00:00 to 23:59
means that no restriction is pending and the burner
can start at any time.
!
ATTENTION
- In order to protect against frost,
only automatic start-up of the heating circuit
pump is active outside the release time.
14
Operation manual
pelletelegance